    AI mammogram reading raises cancer detection at RadNet

    RadNet pairs DeepHealth breast AI with a second specialist review of high-suspicion mammograms in its US imaging centers, offered to patients as the Enhanced Breast Cancer Detection add-on.

    RadNetUnited States (RadNet-affiliated imaging centers nationwide; the ASSURE study covered sites in California, Delaware, Maryland and New York)Hospitals and health systemsScaled since May 2022
    Scale
    Roughly 600,000 mammograms run through AI each year
    Scenario
    AI-assisted mammogram reading in breast screening
    Business function
    Clinical care
    Who built it
    Built in-house
    Human oversight
    Assists people
    Organization
    Enterprise, 10,000 to 99,999 employees
    AI types
    Computer vision
    Users
    96 radiologists
    Sites
    109 sites

    Sources and their publishers

    This case study draws on reporting by the following publishers. Enterprise AI Case Studies combined these accounts and added its own explanation. The reporting, and every passage quoted from it, belongs to whoever published or supplied it.

    1. RadNet

    2. Nature Health

    3. Radiological Society of North America

    4. Spectrum News

    tl;drCancer detection rose 21.6% in 208,891 screening exams read with RadNet's AI workflow.See the results

    View the solutionBuild this solution yourself

    RadNet, the US outpatient imaging provider, uses DeepHealth breast AI to read 3D screening mammograms and to send suspicious exams that a radiologist cleared to a second breast imaging specialist2, 3. Patients choose the workflow as an add-on called Enhanced Breast Cancer Detection (EBCD)5.

    DeepHealth is RadNet’s AI subsidiary, and EBCD has run nationwide at RadNet-affiliated centers since 20232. In a study of 579,583 screening exams, the AI workflow raised the cancer detection rate by 21.6% against the prior standard of care3.

    In November 2026, RadNet’s quarterly filing cited a 21% increase in cancer detection rates in breast screening for its DeepHealth products1. RadNet operated 439 centers at the end of September 20261.

    Before the deployment

    Before the AI workflow, one radiologist read each screening exam made with digital breast tomosynthesis (DBT), a 3D form of mammography3. The radiologists had non-AI computer-aided detection outputs from Hologic’s ImageChecker3.

    • Single reading: US screening is annual and opportunistic, with one reader per DBT exam3.
    • No double reading: The second reader that European programs use isn’t standard in the USA3.
    • Dense breasts: Dense tissue can mask lesions, and women with dense breasts face higher risk and more missed diagnoses3.
    • No reimbursement: In December 2024, insurance didn’t yet reimburse AI in mammography4.

    What was built

    The workflow puts AI at two points of a screening read: a detection model on every exam, and a safeguard review of exams the model rates as suspicious but the radiologist didn’t recall3. Software, radiologists and patients divide the work:

    • Detection model: DeepHealth Breast AI version 2.x rates each exam’s suspicion of cancer as minimal, low, intermediate or high. It draws boxes around suspicious lesions3.
    • Interpreting radiologist: Reads the exam with the AI output and decides whether to recall the patient3, 5.
    • SafeGuard Review: Sends each exam above a set AI threshold that the radiologist didn’t recall to a breast imaging specialist3.
    • Specialist reviewer: Practice leadership picks reviewers for experience and clinical record. If the reviewer finds the exam suspicious, they discuss it with the interpreting radiologist, who makes the final recall decision3.
    • Patients: Opt in to EBCD for a fee that one patient put at about $405. Members of capitated medical groups that cover EBCD aren’t asked to enroll6.

    “The AI-driven enhanced review program leverages AI in a novel workflow to ensure women with suspicious findings get expert level care that could help detect many more breast cancers early.”

    Bryan Haslam, study lead author at DeepHealth4

    Rollout

    Figure 1From five practices to a nationwide add-on
    From five practices to a nationwide add-onThe AI workflow went live on all eligible screening exams at five practices on May 20, 2022. RadNet launched EBCD nationwide in 2023. First-year self-pay results were presented at RSNA on December 5, 2024. Desert Oasis Healthcare began paying for EBCD on October 1, 2025, and the ASSURE study was published in Nature Health on November 17, 2025.20 May 202220 May 2022 · Live at five practices · Documented in source [3]Live at five practices20232023 · EBCD launched nationwide · Documented in source [2]EBCD launched nationwide5 Dec 20245 Dec 2024 · Self-pay results at RSNA 2024 · Documented in source [4]Self-pay results at RSNA 20241 Oct 20251 Oct 2025 · Desert Oasis Healthcare starts paying · Documented in source [6]Desert Oasis Healthcare starts paying17 Nov 202517 Nov 2025 · ASSURE published in Nature Health · Documented in source [3]ASSURE published in Nature HealthFrom five practices to a nationwide add-onThe AI workflow went live on all eligible screening exams at five practices on May 20, 2022. RadNet launched EBCD nationwide in 2023. First-year self-pay results were presented at RSNA on December 5, 2024. Desert Oasis Healthcare began paying for EBCD on October 1, 2025, and the ASSURE study was published in Nature Health on November 17, 2025.20 May 202220 May 2022 · Live at five practices · Documented in source [3]Live at five practices1 yr20232023 · EBCD launched nationwide · Documented in source [2]EBCD launchednationwide2 yrs5 Dec 20245 Dec 2024 · Self-pay results at RSNA 2024 · Documented in source [4]Self-pay resultsat RSNA 202410 mo1 Oct 20251 Oct 2025 · Desert Oasis Healthcare starts paying · Documented in source [6]Desert OasisHealthcarestarts paying1 mo17 Nov 202517 Nov 2025 · ASSURE published in Nature Health · Documented in source [3]ASSURE publishedin Nature Health
    • Key milestone
    Sources [2][3][4][6]
    The workflow went live at five practices in 2022 and became a nationwide program a year later.

    Radiologists had two months to adapt before ASSURE data collection started on August 3, 20223. In the third quarter of 2025, Regal Medical Group, Lakeside Community Healthcare, ADOC Medical Group and Desert Oasis Healthcare agreed to pay for EBCD6.

    Technology and architecture

    Figure 2Where the AI sits in a RadNet screening read
    Where the AI sits in a RadNet screening readA 3D mammography (DBT) exam goes to DeepHealth Breast AI, which scores its suspicion of cancer. The AI output reaches the interpreting radiologist through the imaging viewing software; that handoff through the viewer is inferred. The radiologist decides on recall. Exams the radiologist didn't recall and that score above the AI threshold go through SafeGuard Review to a breast imaging specialist, who gives feedback to the radiologist before the final recall decision.DBT images (data) · Documented in source [3]suspicion level, boxes (data) · Inferred, not documented in the sourcesAI-marked exam (handoff to people) · Inferred, not documented in the sourcessuspicion score (data) · Documented in source [3]exams not recalled (data) · Documented in source [3]above-threshold exams (handoff to people) · Documented in source [3]discussion (feedback) · Documented in source [3]final decision (trigger or control) · Documented in source [3]DBT screening exam · Device · Documented in source [3]DEVICEDBT screeningexamDeepHealth Breast AI · AI model · Documented in source [3]AI MODELDeepHealthBreast AIImaging viewing software · Application · Documented in source [3]APPLICATIONImagingviewingsoftwareInterpreting radiologist · Person · Documented in source [3]PERSONInterpretingradiologistSafeGuard Review · System · Documented in source [3]SYSTEMSafeGuardReviewBreast imaging specialist · Person · Documented in source [3]PERSONBreast imagingspecialistRecall decision · Decision · Documented in source [3]DECISIONRecall decisionDBT imagessuspicionlevel, boxesAI-markedexamsuspicion scoreexams notrecalledabove-thresholdexamsdiscussionfinal decisionWhere the AI sits in a RadNet screening readA 3D mammography (DBT) exam goes to DeepHealth Breast AI, which scores its suspicion of cancer. The AI output reaches the interpreting radiologist through the imaging viewing software; that handoff through the viewer is inferred. The radiologist decides on recall. Exams the radiologist didn't recall and that score above the AI threshold go through SafeGuard Review to a breast imaging specialist, who gives feedback to the radiologist before the final recall decision.DBT images (data) · Documented in source [3]suspicion level, boxes (data) · Inferred, not documented in the sourcesAI-marked exam (handoff to people) · Inferred, not documented in the sourcessuspicion score (data) · Documented in source [3]exams not recalled (data) · Documented in source [3]above-threshold exams (handoff to people) · Documented in source [3]discussion (feedback) · Documented in source [3]final decision (trigger or control) · Documented in source [3]DBT screening exam · Device · Documented in source [3]DEVICEDBT screening examDeepHealth Breast AI · AI model · Documented in source [3]AI MODELDeepHealth Breast AIImaging viewing software · Application · Documented in source [3]APPLICATIONImaging viewingsoftwareInterpreting radiologist · Person · Documented in source [3]PERSONInterpreting radiologistSafeGuard Review · System · Documented in source [3]SYSTEMSafeGuard ReviewBreast imaging specialist · Person · Documented in source [3]PERSONBreast imagingspecialistRecall decision · Decision · Documented in source [3]DECISIONRecall decisionDBT imagessuspicion level, boxesAI-marked examsuspicion scoreexams not recalledabove-threshold examsdiscussionfinal decision
    • AI component
    • Data
    • Trigger or control
    • Handoff to people
    • Feedback
    • Inferred, not documented
    Source [3]
    The model reads every exam, and a specialist sees only the flagged exams that the radiologist cleared.

    The workflow runs on the applications of DeepHealth Breast Suite2. The AI’s marks most likely appear in the radiologists’ existing viewer, because the workflow is integrated with it.

    Layer What they used Role Source
    Vision model DeepHealth Breast AI version 2.x Rates each exam’s suspicion of cancer in four levels and boxes suspicious lesions 3
    Workflow engine SafeGuard Review Routes above-threshold exams the radiologist didn’t recall to a specialist 2, 3
    Solution platform DeepHealth Breast Suite The DeepHealth applications that run the EBCD workflow 2
    Workplace application Imaging viewing software The radiologists’ existing viewer, which the AI workflow is integrated with 3
    Cameras and imaging Digital breast tomosynthesis (DBT) Produces the 3D screening mammograms that the model reads 3

    Data and integrations

    • Screening exams: Bilateral DBT exams from an eligible manufacturer, for women aged 35 or older, are what the model reads3.
    • Outcome records: BI-RADS assessments, breast density, self-reported race and ethnicity, and biopsy results measure the workflow’s effect3.
    • Imaging viewing software: The AI workflow is integrated with the radiologists’ existing viewer3.

    Results

    The ASSURE study compared exams read with the AI workflow from August to December 2022 against exams read before deployment, from September 2021 to May 20223. Sites, radiologists and patient characteristics were comparable in the two cohorts3.

    Metric Before After Scope and timeframe Reported by
    Cancer detection rate 4.6 per 1,000 exams 5.6 per 1,000 exams, up 21.6% 579,583 exams at 109 sites, 2021 to 2022 DeepHealth, measured3, 2
    Positive predictive value of recalls 4.4% 5.0%, up 15.0% Same exams, 2021 to 2022 DeepHealth, measured3
    Cancer detection rate, dense breasts Not disclosed Up 22.7% Women with dense breasts, ASSURE study DeepHealth, measured3, 2
    Patients opting in to EBCD Not disclosed above 45% Nationwide, third quarter of 2025 RadNet, measured6
    • Cancer detection rate: Biopsy-proven cancers among recalled exams, per 1,000 exams. It rose 21.6%, from 4.6 to 5.6 per 1,000, across 208,891 AI exams and 370,692 earlier exams3.
    • Positive predictive value (PPV1): The share of recalls that ended in a cancer diagnosis. It rose 15.0%, from 4.4% to 5.0%3.
    • Subgroups: Detection rose 22.7% for women with dense breasts, 20.4% for Black women and 21.8% for Hispanic women3.
    • Second reviews: The AI sent 16,763 exams, 8.0% of the total, to a specialist, and zero adverse events were reported3.
    • Self-pay program: Across 747,604 women in 10 practices, the detection rate was 43% higher for enrolled women. Researchers attributed 21% of the increase to the AI program4.
    • Adoption: RadNet put blended national adoption above 45% in November 20256. About 600,000 mammograms a year run through the AI5.

    In November 2026, RadNet reported that EBCD program revenue grew 16.9% in the third quarter of 2026 from a year earlier7. EBCD AI revenue had grown 28.7% in the third quarter of 20256.

    Lessons learned

    The workflow was measured at scale in community imaging centers, not an academic setting: 579,583 exams, 109 sites and 96 radiologists in four states3. Detection rose in every prespecified subgroup by density and by race and ethnicity3.

    The safeguard design answered the single-reader problem with little added work. Only 8% of exams needed a second review, which the authors say gives nearly the full detection benefit of double reading for under 10% of the added effort3.

    More women were called back. The recall rate rose 5.7%, from 10.6% to 11.1% of screening exams, although the higher PPV1 means a larger share of recalls found cancer3.

    The study design has two limits that its authors name. The two cohorts ran one after the other, which controls for confounders less well than a randomized trial. The study also measures the detection model and the SafeGuard Review together, because the workflow combines them3.

    Selling the AI as an add-on mixes its effect with who pays for it. In the self-pay program, 22% of the 43% detection gap came from higher-risk women enrolling more often, and the researchers called for randomized trials to remove that bias4. ASSURE gave the workflow to all patients at no charge for that reason2.

    Insurance coverage lags. In November 2025, RadNet’s chief executive Howard Berger said of commercial payers, “We are in discussions. It’s a big ship, and they turn slowly,” and patients kept opting in to pay out of pocket6, 5. The adoption figures differ by date: 36% in December 20244, above 45% in November 20256 and about 40% in February 20265.

    The detection figures are DeepHealth’s own. Seven ASSURE authors are DeepHealth employees or shareholders and two are its consultants, and the study data are DeepHealth intellectual property3.

    Case study scorecard

    Build this solution yourself

    Analysis

    What you need

    • A detection model cleared for your scanners: The workflow only runs on bilateral DBT exams from eligible manufacturers, so check that your fleet qualifies3.
    • A pool of trusted breast specialists: The SafeGuard Review depends on reviewers whom practice leadership selects for their record, and who can reach the reading radiologist3.
    • A way to pay for it: RadNet relied on patient fees and capitated groups because insurers didn’t reimburse the AI, so you need a funding model before you offer it to everyone4, 6.
    • Before-and-after outcome data: The results rest on recall and biopsy records from the same sites and radiologists before and after go-live3.

    Reference architecture

    Visual inspection and monitoring

    A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.

    A check mark shows a building block that this case study's sources document.

    Open the reference architecture

    Others who built it

    Cite this case study

    Enterprise AI Case Studies. "AI mammogram reading raises cancer detection at RadNet." Updated Nov 26, 2026. https://case-studies.ai/case-studies/operational-technology/OT-065-ai-mammography-ebcd-radnet/

    @misc{csai-ot-065,
      author = {{Enterprise AI Case Studies}},
      title = {{AI mammogram reading raises cancer detection at RadNet}},
      year = {2026},
      note = {Updated 2026-11-26},
      url = {https://case-studies.ai/case-studies/operational-technology/OT-065-ai-mammography-ebcd-radnet/}
    }

    Sources

    The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership

    1. Source 1:

      RadNet, Inc. Form 10-Q for the quarter ended September 30, 2026

      OrganizationRadNet, Nov 9, 20269 Nov 2026FilingAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (2)
      • At September 30, 2026, we operated directly, or indirectly through joint ventures with hospitals and health system partners, 439 centers
      • Clinical outcomes demonstrate strong performance, including a 21% increase in cancer detection rates in breast screening.
    2. Source 2:

      Landmark Nature Health Study Demonstrates the Effectiveness of DeepHealth's Novel AI-Powered Breast Cancer Detection Workflow

      OrganizationRadNet, Nov 17, 202517 Nov 2025Accessed Nov 26, 202626 Nov 2026

      Supporting excerpts (11)
      • This study included mammograms from over 579,000 women across 109 community-based imaging sites in California, Delaware, Maryland and New York.
      • FDA-cleared computer-aided detection and diagnosis (CADe/x) software with an AI-supported Safeguard Review workflow, which can trigger a second breast imaging expert review of high-suspicion cases
      • Launched nationwide at RadNet-affiliated centers in 2023
      • This workflow is enabled by the applications that make up DeepHealth
      • To avoid potential selection bias, the AI-enabled workflow was provided to all patients at no additional charge during the study period.
      • Unlike many academically focused studies, these screenings took place at community imaging centers, where most women get their mammograms
      • There has never been a similar study of this size in the United States, much less one with such a diverse patient population, that examines the patient impact and efficacy of AI-assisted breast cancer screening.
      • RadNet has about 11,000 team members
      • maintaining recall rates within American College of Radiology guidelines
      • delivered a 22.7% boost in cancer detection rate compared to 3D mammography screening for women with dense breasts
      • led to a 21.6% increase in cancer detection rate compared to state-of-the-art 3D mammography screening
    3. Source 3:

      Equitable impact of an AI-driven breast cancer screening workflow in real-world US-wide deployment

      AcademicNature Health, Nov 17, 202517 Nov 2025By Leeann D. LouisAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (38)
      • Comparing the AI-driven workflow (N = 208,891) with the prior standard of care (N = 370,692) resulted in a +21.6% increase in cancer detection rate (CDR; 5.6 versus 4.6 per 1,000), +5.7% recall rate (RR; 11.1% versus 10.6%) and +15.0% positive predictive value (PPV1; 5.0% versus 4.4%).
      • The CDR was 22.7% higher for women with dense breasts with versus without the multistage AI-driven workflow
      • Black and Hispanic women showed large relative improvements in their CDR (20.4% and 21.8%, respectively).
      • Real-world deployment of the multistage AI-driven workflow was conducted at 5 practices across the USA (109 sites, 96 radiologists)
      • This study included 579,583 exams: 370,692 (64%) in standard of care and 208,891 (36%) in the multistage AI-driven workflow.
      • The CADe/x device provides an overall four-level category (minimal, low, intermediate and high) of suspicion for cancer and localized bounding boxes for suspicious lesions
      • interpreting the mammogram with a computer-aided detection and diagnosis (CADe/x) device (DeepHealth Breast AI version 2.x, DeepHealth) and an AI-supported SafeGuard Review
      • The SafeGuard Review routes exams above a predetermined DeepHealth Breast AI threshold that were not recalled by the interpreting radiologist for review by a breast imaging specialist (reviewer).
      • Reviewers were selected by the breast imaging practice leadership based on experience and clinical performance record.
      • If the reviewer agreed with the AI and found the exam suspicious, they discussed the exam with the interpreting radiologist, who made the final recall decision.
      • The standard-of-care workflow consisted of single reading of DBT exams without the use of the multistage AI-driven workflow.
      • Radiologists in both cohorts had access to non-AI-based computer-aided detection outputs (ImageChecker, Hologic).
      • The multistage AI-driven workflow was deployed on all exams satisfying the product instructions for use from 20 May 2022 to 31 December 2022
      • Data were collected from 3 August 2022 to 31 December 2022, starting 2 months after deployment to allow radiologists to adapt to the new technology
      • Exams between 1 September 2021 and 19 May 2022 did not receive the multistage AI-driven workflow and formed the standard-of-care comparison cohort.
      • Out of the 208,891 exams that went through the multistage AI-driven workflow, 16,763 underwent an additional safeguard review (8.0% of all exams).
      • Zero adverse events were reported during the study period.
      • This enables nearly the full cancer detection benefits of double reading for <10% of the added effort and the cost of the software.
      • highlighting the efficiency of combining a CADe/x device with a safeguard review in which only 8% of cases required a second review
      • However, double reading is not standard in the USA
      • This paradigm substantially differs from US practice with annual, opportunistic screening and single-reading workflows with digital breast tomosynthesis (DBT).
      • women with dense breast tissue that can mask cancer lesions in mammograms face higher cancer risk and greater likelihood of missed cancer diagnoses
      • integration with existing imaging viewing software
      • Finally, the cohorts were divided into two sequential groups in this real-world observational study, which does not control for unknown biases and confounders in the patient groups as a randomized trial would.
      • it was not possible to extract the clinical impact of the CADe/x device from the SafeGuard Review
      • a double-blind randomized control trial was not possible as the reading radiologists could not use the device while blinded
      • Data were collected in compliance with the Health Insurance Portability and Accountability Act
      • Exams were included only if they were bilateral, DBT, and were from an eligible manufacturer.
      • Patient criteria: ≥35 years old and self-reported as female.
      • Clinical outcomes were stratified by breast density and racial subgroups to assess whether outcomes were equitable
      • radiologists improved sensitivity (80.8% without versus 89.6% with the device, P < 0.01) and did not reduce specificity
      • Adverse events were monitored as part of post-market surveillance activities.
      • L.D.L., E.A.W., M.M., A.Y.N., J.G.K., B.H. and A.G.S. are employees and/or shareholders of DeepHealth Inc. C.I.L. and D.S.M.B. are consultants to DeepHealth Inc.
      • The data that support the findings of this study form part of DeepHealth Inc. intellectual property
      • The CDR was defined as the number of BI-RADS 0 (positive) exams with a malignant biopsy
      • The RR was defined as the percentage of screening exams that were positive. The PPV1 was defined as the percentage of positive exams that resulted in a malignant biopsy.
      • Exam data collected included screening BI-RADS assessment and breast density
      • the sites, interpreting radiologists and patient characteristics are comparable in the two cohorts
    4. Source 4:

      Women Pay for AI to Boost Mammogram Findings

      IndependentRadiological Society of North America, Dec 5, 20245 Dec 2024Accessed Nov 26, 202626 Nov 2026

      Supporting excerpts (10)
      • More than a third of women across 10 health care practices chose to enroll in a self-pay, artificial intelligence (AI)-enhanced breast cancer screening program, and the women who enrolled were 21% more likely to have cancer detected
      • Despite its promise, AI is not yet reimbursed by insurance, which likely is slowing its adoption in the clinic.
      • Some practices have elected to offer enhanced workflows enabled by AI at additional cost
      • Out of the 747,604 women who underwent screening mammography over an initial 12-month period, the overall cancer detection rate was on average 43% higher for enrolled women than for unenrolled women.
      • Further analysis attributed 21% of the increase in cancer detection to the AI program. The researchers credited the remaining 22% increase in detection to the fact that higher-risk patients chose to enroll more frequently.
      • the positive predictive value for cancer was 15% higher for the enrolled women
      • The number of women electing for this program is now at 36% and growing
      • The AI-driven enhanced review program leverages AI in a novel workflow to ensure women with suspicious findings get expert level care that could help detect many more breast cancers early.
      • the researchers hope to better quantify the benefit of the AI-driven safeguard review with prospective randomized controlled trials that would eliminate the self-selection bias
      • said study lead author Bryan Haslam, Ph.D., from DeepHealth
    5. Source 5:

      New screening technology flags cancers doctors can miss

      IndependentSpectrum News, Feb 26, 202626 Feb 2026By Genevieve GlassAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (9)
      • an additional fee of like $40
      • That optional add-on is called enhanced breast cancer detection, or EBCD, an FDA-cleared AI technology designed to help radiologists identify cancers earlier.
      • RadNet said that about 40% of patients opt in, with roughly 600,000 mammograms run through AI each year.
      • his team has been using AI-enhanced screening for three years
      • we are seeing an uptick in the detection of cancer by about 21%
      • Dr. Jason McKellop, medical director of breast imaging for Breastlink and RadNet
      • The artificial intelligence, with a click of a button, identified it immediately
      • Research shows there is no added radiation and no extra time during the visit
      • McKellop noted that the process includes a radiologist reviewing the mammogram, then AI analysis, followed by another radiologist who looks at any discrepancies between the two.
    6. Source 6:

      RadNet (RDNT) Q3 2025 Earnings Call Transcript

      OrganizationRadNet, Nov 10, 202510 Nov 2025Accessed Nov 26, 202626 Nov 2026

      Supporting excerpts (8)
      • Currently, we are experiencing a blended adoption rate nationally above 45%
      • During the third quarter, several of our larger capitated medical groups agreed to add EBCD as a covered benefit for over 700,000 members.
      • Regal Medical Group, Lakeside Community Healthcare, ADOC Medical Group, and Desert Oasis Healthcare have agreed to reimburse RadNet, Inc. for its EBCD program.
      • Also contributing to this growth was a 28.7% increase in EBCD AI revenue
      • We are in discussions. It's a big ship, and they turn slowly.
      • Perhaps driving that is the continued growth of adoption by our patients who are opting in to pay it out of pocket.
      • which means we don't ask those patients if they want to enroll in EBCD.
      • on October 1, we had a new capitation Desert Oasis Healthcare
    7. Source 7:

      RadNet (RDNT) Q3 2026 Earnings Call Transcript

      OrganizationRadNet, Nov 9, 20269 Nov 2026Accessed Nov 26, 202626 Nov 2026

      Supporting excerpts (1)
      • revenue from the EBCD program increased 16.9%