AI mammogram reading raises cancer detection at RadNet
RadNet pairs DeepHealth breast AI with a second specialist review of high-suspicion mammograms in its US imaging centers, offered to patients as the Enhanced Breast Cancer Detection add-on.
RadNetUnited States (RadNet-affiliated imaging centers nationwide; the ASSURE study covered sites in California, Delaware, Maryland and New York)Hospitals and health systemsScaled since May 2022
- Scale
- Roughly 600,000 mammograms run through AI each year
- Scenario
- AI-assisted mammogram reading in breast screening
- Business function
- Clinical care
- Kind of solution
- Visual inspection and monitoring
- Who built it
- Built in-house
- Human oversight
- Assists people
- Organization
- Enterprise, 10,000 to 99,999 employees
- AI types
- Computer vision
- Users
- 96 radiologists
- Sites
- 109 sites
tl;drCancer detection rose 21.6% in 208,891 screening exams read with RadNet's AI workflow.See the results
RadNet, the US outpatient imaging provider, uses DeepHealth breast AI to read 3D screening mammograms and to send suspicious exams that a radiologist cleared to a second breast imaging specialist2, 3. Patients choose the workflow as an add-on called Enhanced Breast Cancer Detection (EBCD)5.
DeepHealth is RadNet’s AI subsidiary, and EBCD has run nationwide at RadNet-affiliated centers since 20232. In a study of 579,583 screening exams, the AI workflow raised the cancer detection rate by 21.6% against the prior standard of care3.
In November 2026, RadNet’s quarterly filing cited a 21% increase in cancer detection rates in breast screening for its DeepHealth products1. RadNet operated 439 centers at the end of September 20261.
Before the deployment
Before the AI workflow, one radiologist read each screening exam made with digital breast tomosynthesis (DBT), a 3D form of mammography3. The radiologists had non-AI computer-aided detection outputs from Hologic’s ImageChecker3.
- Single reading: US screening is annual and opportunistic, with one reader per DBT exam3.
- No double reading: The second reader that European programs use isn’t standard in the USA3.
- Dense breasts: Dense tissue can mask lesions, and women with dense breasts face higher risk and more missed diagnoses3.
- No reimbursement: In December 2024, insurance didn’t yet reimburse AI in mammography4.
What was built
The workflow puts AI at two points of a screening read: a detection model on every exam, and a safeguard review of exams the model rates as suspicious but the radiologist didn’t recall3. Software, radiologists and patients divide the work:
- Detection model: DeepHealth Breast AI version 2.x rates each exam’s suspicion of cancer as minimal, low, intermediate or high. It draws boxes around suspicious lesions3.
- Interpreting radiologist: Reads the exam with the AI output and decides whether to recall the patient3, 5.
- SafeGuard Review: Sends each exam above a set AI threshold that the radiologist didn’t recall to a breast imaging specialist3.
- Specialist reviewer: Practice leadership picks reviewers for experience and clinical record. If the reviewer finds the exam suspicious, they discuss it with the interpreting radiologist, who makes the final recall decision3.
- Patients: Opt in to EBCD for a fee that one patient put at about $405. Members of capitated medical groups that cover EBCD aren’t asked to enroll6.
“The AI-driven enhanced review program leverages AI in a novel workflow to ensure women with suspicious findings get expert level care that could help detect many more breast cancers early.”
Rollout
Radiologists had two months to adapt before ASSURE data collection started on August 3, 20223. In the third quarter of 2025, Regal Medical Group, Lakeside Community Healthcare, ADOC Medical Group and Desert Oasis Healthcare agreed to pay for EBCD6.
Technology and architecture
- AI component
- Data
- Trigger or control
- Handoff to people
- Feedback
- Inferred, not documented
The workflow runs on the applications of DeepHealth Breast Suite2. The AI’s marks most likely appear in the radiologists’ existing viewer, because the workflow is integrated with it.
| Layer | What they used | Role | Source |
|---|---|---|---|
| Vision model | DeepHealth Breast AI version 2.x | Rates each exam’s suspicion of cancer in four levels and boxes suspicious lesions | 3 |
| Workflow engine | SafeGuard Review | Routes above-threshold exams the radiologist didn’t recall to a specialist | 2, 3 |
| Solution platform | DeepHealth Breast Suite | The DeepHealth applications that run the EBCD workflow | 2 |
| Workplace application | Imaging viewing software | The radiologists’ existing viewer, which the AI workflow is integrated with | 3 |
| Cameras and imaging | Digital breast tomosynthesis (DBT) | Produces the 3D screening mammograms that the model reads | 3 |
Data and integrations
- Screening exams: Bilateral DBT exams from an eligible manufacturer, for women aged 35 or older, are what the model reads3.
- Outcome records: BI-RADS assessments, breast density, self-reported race and ethnicity, and biopsy results measure the workflow’s effect3.
- Imaging viewing software: The AI workflow is integrated with the radiologists’ existing viewer3.
Results
The ASSURE study compared exams read with the AI workflow from August to December 2022 against exams read before deployment, from September 2021 to May 20223. Sites, radiologists and patient characteristics were comparable in the two cohorts3.
| Metric | Before | After | Scope and timeframe | Reported by |
|---|---|---|---|---|
| Cancer detection rate | 4.6 per 1,000 exams | 5.6 per 1,000 exams, up 21.6% | 579,583 exams at 109 sites, 2021 to 2022 | DeepHealth, measured3, 2 |
| Positive predictive value of recalls | 4.4% | 5.0%, up 15.0% | Same exams, 2021 to 2022 | DeepHealth, measured3 |
| Cancer detection rate, dense breasts | Not disclosed | Up 22.7% | Women with dense breasts, ASSURE study | DeepHealth, measured3, 2 |
| Patients opting in to EBCD | Not disclosed | above 45% | Nationwide, third quarter of 2025 | RadNet, measured6 |
- Cancer detection rate: Biopsy-proven cancers among recalled exams, per 1,000 exams. It rose 21.6%, from 4.6 to 5.6 per 1,000, across 208,891 AI exams and 370,692 earlier exams3.
- Positive predictive value (PPV1): The share of recalls that ended in a cancer diagnosis. It rose 15.0%, from 4.4% to 5.0%3.
- Subgroups: Detection rose 22.7% for women with dense breasts, 20.4% for Black women and 21.8% for Hispanic women3.
- Second reviews: The AI sent 16,763 exams, 8.0% of the total, to a specialist, and zero adverse events were reported3.
- Self-pay program: Across 747,604 women in 10 practices, the detection rate was 43% higher for enrolled women. Researchers attributed 21% of the increase to the AI program4.
- Adoption: RadNet put blended national adoption above 45% in November 20256. About 600,000 mammograms a year run through the AI5.
In November 2026, RadNet reported that EBCD program revenue grew 16.9% in the third quarter of 2026 from a year earlier7. EBCD AI revenue had grown 28.7% in the third quarter of 20256.
Lessons learned
The workflow was measured at scale in community imaging centers, not an academic setting: 579,583 exams, 109 sites and 96 radiologists in four states3. Detection rose in every prespecified subgroup by density and by race and ethnicity3.
The safeguard design answered the single-reader problem with little added work. Only 8% of exams needed a second review, which the authors say gives nearly the full detection benefit of double reading for under 10% of the added effort3.
More women were called back. The recall rate rose 5.7%, from 10.6% to 11.1% of screening exams, although the higher PPV1 means a larger share of recalls found cancer3.
The study design has two limits that its authors name. The two cohorts ran one after the other, which controls for confounders less well than a randomized trial. The study also measures the detection model and the SafeGuard Review together, because the workflow combines them3.
Selling the AI as an add-on mixes its effect with who pays for it. In the self-pay program, 22% of the 43% detection gap came from higher-risk women enrolling more often, and the researchers called for randomized trials to remove that bias4. ASSURE gave the workflow to all patients at no charge for that reason2.
Insurance coverage lags. In November 2025, RadNet’s chief executive Howard Berger said of commercial payers, “We are in discussions. It’s a big ship, and they turn slowly,” and patients kept opting in to pay out of pocket6, 5. The adoption figures differ by date: 36% in December 20244, above 45% in November 20256 and about 40% in February 20265.
The detection figures are DeepHealth’s own. Seven ASSURE authors are DeepHealth employees or shareholders and two are its consultants, and the study data are DeepHealth intellectual property3.
Case study scorecard
- 21.6% Increase in cancer detection rate3, 2
- 15.0% Increase in positive predictive value of recalls3
- 22.7% Increase in cancer detection rate for women with dense breasts3, 2
- above 45% Patients opting in to EBCD nationally6
- Source quality: 94%, High quality. Rests on a peer-reviewed paper.
- Rules and standards: HIPAA, Medical device rules
Sources by publication date
- Organization 4
- Press, academic, and regulators 3
Build this solution yourself
Analysis
What you need
- A detection model cleared for your scanners: The workflow only runs on bilateral DBT exams from eligible manufacturers, so check that your fleet qualifies3.
- A pool of trusted breast specialists: The SafeGuard Review depends on reviewers whom practice leadership selects for their record, and who can reach the reading radiologist3.
- A way to pay for it: RadNet relied on patient fees and capitated groups because insurers didn’t reimburse the AI, so you need a funding model before you offer it to everyone4, 6.
- Before-and-after outcome data: The results rest on recall and biopsy records from the same sites and radiologists before and after go-live3.
Reference architecture
Visual inspection and monitoring
A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.
- Cameras and imaging (documented in this case study)
- Field network
- Device or line-side computer
- Privacy masking
- Vision model (documented in this case study)
- Inspection platform (documented in this case study)
- Thresholds and routing rules
- Risk or priority model
- Line or equipment controller
- Business or operational system
- Alert console
- Review screen
- Notifications
- Image and results store
- Verdict capture
- Model training environment
A check mark shows a building block that this case study's sources document.
Open the reference architectureOthers who built it
- Renault Group: Renault scales AI visual inspection to 500 checks per plant. Renault's plants went from 10 AI-based inspection controls each in 2021 to 500 in 2025.
- Happy Returns: AI return audits catch item swaps at Happy Returns. About 10% of the returns flagged for an AI audit in the pilot turned out to be fraud.
- Walmart: Walmart tracks pallets with Wiliot IoT sensors and AI. Wiliot sensors feeding Walmart's AI ran at 500 locations, replacing manual tasks with alerts.
- Van de Velde: Van de Velde sizes bras from two smartphone photos with AI. More than 65% of BraSizeScan's size advice matches professional fitting, in a few seconds.
- Siemens: Synthetic boards train Siemens' inspection AI at Erlangen. At Erlangen, Siemens prepares circuit board inspection before the first physical board exists.
- Intel: AI progress monitoring cuts rework on Intel's fab builds. Intel estimates the platform cut rework costs 4.3% and avoided about 4 weeks of delay per fab.
Cite this case study
Enterprise AI Case Studies. "AI mammogram reading raises cancer detection at RadNet." Updated Nov 26, 2026. https://case-studies.ai/case-studies/operational-technology/OT-065-ai-mammography-ebcd-radnet/
@misc{csai-ot-065,
author = {{Enterprise AI Case Studies}},
title = {{AI mammogram reading raises cancer detection at RadNet}},
year = {2026},
note = {Updated 2026-11-26},
url = {https://case-studies.ai/case-studies/operational-technology/OT-065-ai-mammography-ebcd-radnet/}
}Sources
The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership
- Source 1:
RadNet, Inc. Form 10-Q for the quarter ended September 30, 2026
Supporting excerpts (2)
At September 30, 2026, we operated directly, or indirectly through joint ventures with hospitals and health system partners, 439 centers
Clinical outcomes demonstrate strong performance, including a 21% increase in cancer detection rates in breast screening.
- Source 2:
Supporting excerpts (11)
This study included mammograms from over 579,000 women across 109 community-based imaging sites in California, Delaware, Maryland and New York.
FDA-cleared computer-aided detection and diagnosis (CADe/x) software with an AI-supported Safeguard Review workflow, which can trigger a second breast imaging expert review of high-suspicion cases
Launched nationwide at RadNet-affiliated centers in 2023
This workflow is enabled by the applications that make up DeepHealth
To avoid potential selection bias, the AI-enabled workflow was provided to all patients at no additional charge during the study period.
Unlike many academically focused studies, these screenings took place at community imaging centers, where most women get their mammograms
There has never been a similar study of this size in the United States, much less one with such a diverse patient population, that examines the patient impact and efficacy of AI-assisted breast cancer screening.
RadNet has about 11,000 team members
maintaining recall rates within American College of Radiology guidelines
delivered a 22.7% boost in cancer detection rate compared to 3D mammography screening for women with dense breasts
led to a 21.6% increase in cancer detection rate compared to state-of-the-art 3D mammography screening
- Source 3:
Equitable impact of an AI-driven breast cancer screening workflow in real-world US-wide deployment
Supporting excerpts (38)
Comparing the AI-driven workflow (N = 208,891) with the prior standard of care (N = 370,692) resulted in a +21.6% increase in cancer detection rate (CDR; 5.6 versus 4.6 per 1,000), +5.7% recall rate (RR; 11.1% versus 10.6%) and +15.0% positive predictive value (PPV1; 5.0% versus 4.4%).
The CDR was 22.7% higher for women with dense breasts with versus without the multistage AI-driven workflow
Black and Hispanic women showed large relative improvements in their CDR (20.4% and 21.8%, respectively).
Real-world deployment of the multistage AI-driven workflow was conducted at 5 practices across the USA (109 sites, 96 radiologists)
This study included 579,583 exams: 370,692 (64%) in standard of care and 208,891 (36%) in the multistage AI-driven workflow.
The CADe/x device provides an overall four-level category (minimal, low, intermediate and high) of suspicion for cancer and localized bounding boxes for suspicious lesions
interpreting the mammogram with a computer-aided detection and diagnosis (CADe/x) device (DeepHealth Breast AI version 2.x, DeepHealth) and an AI-supported SafeGuard Review
The SafeGuard Review routes exams above a predetermined DeepHealth Breast AI threshold that were not recalled by the interpreting radiologist for review by a breast imaging specialist (reviewer).
Reviewers were selected by the breast imaging practice leadership based on experience and clinical performance record.
If the reviewer agreed with the AI and found the exam suspicious, they discussed the exam with the interpreting radiologist, who made the final recall decision.
The standard-of-care workflow consisted of single reading of DBT exams without the use of the multistage AI-driven workflow.
Radiologists in both cohorts had access to non-AI-based computer-aided detection outputs (ImageChecker, Hologic).
The multistage AI-driven workflow was deployed on all exams satisfying the product instructions for use from 20 May 2022 to 31 December 2022
Data were collected from 3 August 2022 to 31 December 2022, starting 2 months after deployment to allow radiologists to adapt to the new technology
Exams between 1 September 2021 and 19 May 2022 did not receive the multistage AI-driven workflow and formed the standard-of-care comparison cohort.
Out of the 208,891 exams that went through the multistage AI-driven workflow, 16,763 underwent an additional safeguard review (8.0% of all exams).
Zero adverse events were reported during the study period.
This enables nearly the full cancer detection benefits of double reading for <10% of the added effort and the cost of the software.
highlighting the efficiency of combining a CADe/x device with a safeguard review in which only 8% of cases required a second review
However, double reading is not standard in the USA
This paradigm substantially differs from US practice with annual, opportunistic screening and single-reading workflows with digital breast tomosynthesis (DBT).
women with dense breast tissue that can mask cancer lesions in mammograms face higher cancer risk and greater likelihood of missed cancer diagnoses
integration with existing imaging viewing software
Finally, the cohorts were divided into two sequential groups in this real-world observational study, which does not control for unknown biases and confounders in the patient groups as a randomized trial would.
it was not possible to extract the clinical impact of the CADe/x device from the SafeGuard Review
a double-blind randomized control trial was not possible as the reading radiologists could not use the device while blinded
Data were collected in compliance with the Health Insurance Portability and Accountability Act
Exams were included only if they were bilateral, DBT, and were from an eligible manufacturer.
Patient criteria: ≥35 years old and self-reported as female.
Clinical outcomes were stratified by breast density and racial subgroups to assess whether outcomes were equitable
radiologists improved sensitivity (80.8% without versus 89.6% with the device, P < 0.01) and did not reduce specificity
Adverse events were monitored as part of post-market surveillance activities.
L.D.L., E.A.W., M.M., A.Y.N., J.G.K., B.H. and A.G.S. are employees and/or shareholders of DeepHealth Inc. C.I.L. and D.S.M.B. are consultants to DeepHealth Inc.
The data that support the findings of this study form part of DeepHealth Inc. intellectual property
The CDR was defined as the number of BI-RADS 0 (positive) exams with a malignant biopsy
The RR was defined as the percentage of screening exams that were positive. The PPV1 was defined as the percentage of positive exams that resulted in a malignant biopsy.
Exam data collected included screening BI-RADS assessment and breast density
the sites, interpreting radiologists and patient characteristics are comparable in the two cohorts
- Source 4:
Women Pay for AI to Boost Mammogram Findings
Supporting excerpts (10)
More than a third of women across 10 health care practices chose to enroll in a self-pay, artificial intelligence (AI)-enhanced breast cancer screening program, and the women who enrolled were 21% more likely to have cancer detected
Despite its promise, AI is not yet reimbursed by insurance, which likely is slowing its adoption in the clinic.
Some practices have elected to offer enhanced workflows enabled by AI at additional cost
Out of the 747,604 women who underwent screening mammography over an initial 12-month period, the overall cancer detection rate was on average 43% higher for enrolled women than for unenrolled women.
Further analysis attributed 21% of the increase in cancer detection to the AI program. The researchers credited the remaining 22% increase in detection to the fact that higher-risk patients chose to enroll more frequently.
the positive predictive value for cancer was 15% higher for the enrolled women
The number of women electing for this program is now at 36% and growing
The AI-driven enhanced review program leverages AI in a novel workflow to ensure women with suspicious findings get expert level care that could help detect many more breast cancers early.
the researchers hope to better quantify the benefit of the AI-driven safeguard review with prospective randomized controlled trials that would eliminate the self-selection bias
said study lead author Bryan Haslam, Ph.D., from DeepHealth
- Source 5:
New screening technology flags cancers doctors can miss
Supporting excerpts (9)
an additional fee of like $40
That optional add-on is called enhanced breast cancer detection, or EBCD, an FDA-cleared AI technology designed to help radiologists identify cancers earlier.
RadNet said that about 40% of patients opt in, with roughly 600,000 mammograms run through AI each year.
his team has been using AI-enhanced screening for three years
we are seeing an uptick in the detection of cancer by about 21%
Dr. Jason McKellop, medical director of breast imaging for Breastlink and RadNet
The artificial intelligence, with a click of a button, identified it immediately
Research shows there is no added radiation and no extra time during the visit
McKellop noted that the process includes a radiologist reviewing the mammogram, then AI analysis, followed by another radiologist who looks at any discrepancies between the two.
- Source 6:
RadNet (RDNT) Q3 2025 Earnings Call Transcript
Supporting excerpts (8)
Currently, we are experiencing a blended adoption rate nationally above 45%
During the third quarter, several of our larger capitated medical groups agreed to add EBCD as a covered benefit for over 700,000 members.
Regal Medical Group, Lakeside Community Healthcare, ADOC Medical Group, and Desert Oasis Healthcare have agreed to reimburse RadNet, Inc. for its EBCD program.
Also contributing to this growth was a 28.7% increase in EBCD AI revenue
We are in discussions. It's a big ship, and they turn slowly.
Perhaps driving that is the continued growth of adoption by our patients who are opting in to pay it out of pocket.
which means we don't ask those patients if they want to enroll in EBCD.
on October 1, we had a new capitation Desert Oasis Healthcare
- Source 7:
RadNet (RDNT) Q3 2026 Earnings Call Transcript
Supporting excerpts (1)
revenue from the EBCD program increased 16.9%
Comments
Start the conversation.
Invited members of the library comment here. Sign in to join the conversation.