LUMC drafts radiotherapy plans in 1 to 2 hours with AI
Leiden University Medical Center uses AI in RayStation to outline healthy organs on CT scans and draft radiation plans for head and neck cancer, which lab technicians then check and refine.
Leiden University Medical CenterNetherlandsHospitals and health systemsIn production
- Scenario
- AI radiotherapy treatment planning
- Business function
- Clinical care
- Who built it
- Built with a partner (RaySearch Laboratories and TU Delft)
- Human oversight
- People approve each output
- Organization
- Academic or research
- AI types
- Machine learning, Computer vision, Optimization
tl;drRadiation plans that took up to 8 hours by hand are ready in 1 to 2 hours with AI at LUMC.See the results
Leiden University Medical Center (LUMC) uses AI to outline healthy organs on CT scans and draft radiation plans for head and neck cancer patients2. Lab technicians check and refine each AI proposal1.
The plans are made in RayStation, whose deep learning autoplanning predicts a dose for the patient’s anatomy and turns it into a deliverable plan3. As reported in May 2025, a radiation plan that once took up to 8 hours by hand is ready in 1 to 2 hours1.
Before the deployment
Before the AI, radiotherapy lab technicians at LUMC drafted radiation plans entirely by hand1. Staff outlined the tumor and the surrounding organs on CT scans in the RayStation radiation planning software, and then built the plan1.
- Planning time: A plan could take up to 8 hours1.
- Contouring: Placing organs on CT scans is a time-consuming process1.
- Precision: Head and neck tumors sit close to salivary glands and swallowing muscles, which the plan must spare2.
- Consistency: Manual planning by radiation therapy technicians produces inconsistent plans3.
What was built
The solution adds two AI steps to radiotherapy planning at LUMC: automatic outlining of healthy organs, and an AI-drafted radiation plan that staff then refine1, 2. It started with oral cavity cancer1. The AI, the planning software and three groups of staff divide the work:
- Contouring AI: Recognizes the contours of the healthy organs on the CT scan1.
- Radiotherapists: Outline the tumor by hand, to ensure accuracy2.
- Deep learning autoplanning: Predicts a dose distribution from the CT scan and the contours, and turns it into a deliverable plan3.
- Lab technicians: Check and refine the AI’s proposal, instead of making the first plan themselves1.
- Radiation oncologist and clinical physicist: Give their professional opinion before the patient receives the dose3.
“AI’s proposal is often already largely correct and therefore the radiation plan is ready much faster”
Rollout
RaySearch tuned the model on a few earlier LUMC plans in several rounds, and LUMC medical staff approved the final tuning before clinical use3. HagaZiekenhuis and HMC are working on applications for lung and prostate cancer1.
Technology and architecture
RayStation is a treatment planning system from RaySearch Laboratories3. At LUMC, it holds the CT scans and contours, and it runs the deep learning autoplanning (DLAP) module1, 3. DLAP generates a plan in about fifteen minutes3.
- Dose prediction: A U-Net, a type of convolutional neural network, predicts a 3D dose distribution from the CT image and the contours3.
- Dose mimicking optimization: The predicted dose isn’t deliverable as it stands. The optimizer builds a plan whose deliverable dose comes as close to it as possible while working toward preset clinical goals3.
- Institution tuning: RayStation’s standard oropharynx model is the same for every center, so RaySearch tunes it to LUMC’s own plans3.
| Layer | What they used | Role | Source |
|---|---|---|---|
| Predictive model | RayStation deep learning autoplanning (DLAP) | Predicts a 3D dose distribution from the CT scan and the contours | 3 |
| Optimizer | Dose mimicking optimization | Turns the predicted dose into a deliverable treatment plan | 3 |
| Vision model | AI organ contouring software | Outlines the healthy organs on each CT scan | 1, 2 |
| Workplace application | RayStation | Planning software where staff outline structures and build plans | 1, 3 |
| Data set | Princess Margaret Cancer Center training plans | Plans of 100 earlier oropharynx patients that the DLAP model learned from | 3 |
Data inputs
- CT scan: Each patient’s CT image is the main case input3.
- Contours: DLAP uses thirty regions of interest, targets and organs at risk, and needs twenty-two of them to generate a plan3.
- Training plans: The oropharynx model learned from the CT images, structures and doses of 100 earlier bilateral patients at the Princess Margaret Cancer Center in Toronto3.
- LUMC tuning plans: RaySearch tunes the model with a few plans of earlier LUMC patients3.
- Validation plans: LUMC medical staff judge the DLAP plans of thirteen patients against LUMC standards for each tuning round3.
Results
| Metric | Before | After | Scope and timeframe | Reported by |
|---|---|---|---|---|
| Time to a ready radiation plan | Up to 8 hours | 1 to 2 hours | Head and neck cancer plans, reported May 2025 | LUMC, via ICT&health, measured1 |
| Outlining organs on CT scans | Not disclosed | about twice as fast | Organ contouring, reported May 2025 | LUMC, via ICT&health, measured1 |
| Reduction in planning time | Not disclosed | about 50% | Head and neck cancer planning, reported May 2025 | LUMC, via Leiden Bio Science Park, measured2 |
- Time to a ready plan: The time from the start of planning to a plan that is ready for treatment. Lab technicians needed up to 8 hours by hand, and with the AI’s first proposal the plan is ready in 1 to 2 hours, as reported in May 20251.
- Organ contouring: AI contouring makes outlining the organs on CT scans about twice as fast1.
- Planning time: Automating the outlining of healthy organs cuts the planning time by about 50%, for head and neck cancer2.
- Dose to the target: In a 2023 comparison with the clinical plans of earlier LUMC patients, DLAP plans gave higher coverage of the planning target volume in all three cohorts3.
The largest cohort in that comparison held 43 oropharynx patients3. By May 2025, LUMC was also using the AI for rectal cancer1.
Lessons learned
The design keeps a person on every plan, and the use grew. Lab technicians refine each proposal and an oncologist and a physicist review it, and LUMC extended the AI from head and neck to rectal cancer1, 3.
The 2023 dose comparison found trade-offs. DLAP plans gave more dose to the mandible in all cohorts, and to the brain stem core in larynx patients3. The analysis of complication probability showed no notable improvement or worsening, while ICT&health describes AI plans as more accurate and gentler on swallowing muscles1, 3.
The model fell short on cases outside its training. For unilateral oropharynx patients, DLAP didn’t spare the salivary glands and swallowing muscles on the other side enough, because it was trained mainly on bilateral plans3. The study’s author suggests waiting for a model trained for unilateral patients3.
DLAP depends on complete inputs and needed a workaround. It can’t make a plan when a required contour is missing, and LUMC’s tuning needed an extra 2 mm target margin at the swallowing muscles3.
The accounts differ on the training data and the time saved. The 2025 reports describe a model trained on thousands of earlier plans, and the 2023 thesis describes the oropharynx model as trained on 100 plans1, 2, 3. ICT&health gives up to 8 hours for a manual plan, and the thesis gives up to half a day or longer1, 3.
The time figures are LUMC’s own, relayed by ICT&health and Leiden Bio Science Park1, 2. The dose comparison is a TU Delft master’s thesis that an LUMC clinical physicist co-supervised3.
Case study scorecard
- 1 to 2 hours Time to a ready radiation plan1
- about twice as fast Outlining organs on CT scans1
- about 50% Reduction in planning time2
- Source quality: 71%, High quality. Rests on a news report.
Sources by publication date
- Press, academic, and regulators 3
Build this solution yourself
Analysis
What you need
- A planning system with deep learning autoplanning: LUMC’s AI runs inside RayStation, which turns the predicted dose into a deliverable plan3.
- Complete contours for each patient: DLAP needs twenty-two required regions, so your staff must outline them even when a tumor covers an organ3.
- Clinical staff to validate each tuning: LUMC staff judged the plans of thirteen earlier patients per round before approving clinical use3.
- A model trained on your technique: Check that the vendor’s training plans match your cases, because the bilateral model fell short on unilateral patients3.
Cite this case study
Enterprise AI Case Studies. "LUMC drafts radiotherapy plans in 1 to 2 hours with AI." Updated Nov 27, 2026. https://case-studies.ai/case-studies/production-and-quality/PQ-057-ai-radiotherapy-planning-lumc/
@misc{csai-pq-057,
author = {{Enterprise AI Case Studies}},
title = {{LUMC drafts radiotherapy plans in 1 to 2 hours with AI}},
year = {2026},
note = {Updated 2026-11-27},
url = {https://case-studies.ai/case-studies/production-and-quality/PQ-057-ai-radiotherapy-planning-lumc/}
}Sources
The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership
- Source 1:
AI accelerates radiotherapy and protects healthy tissue
Supporting excerpts (14)
At Leiden University Medical Center (LUMC), AI is being used successfully in radiotherapy for oral cavity cancer.
the tumor and surrounding organs are plotted using the RayStation radiation planning software
The lab technician now no longer first makes a plan himself, but instead has AI make a proposal based on thousands of previous treatments worldwide. The lab technician then checks and refines this plan.
AI's proposal is often already largely correct and therefore the radiation plan is ready much faster
says Frank Dankers, clinical physicist in the Radiotherapy Department
Placing organs on CT scans is a time-consuming process.
The AI software automatically recognizes the contours of organs, making the drawing in process about twice as fast.
Radiotherapists need only draw in the tumor manually, saving time and improving workflow.
Previously, radiotherapy lab technicians drafted radiation plans entirely manually, a process that could take up to eight hours.
resulting in a radiation treatment plan that is ready within one to two hours
AI-assisted radiation plans provide a more accurate dose distribution, reducing stress on healthy tissues such as swallowing muscles.
AI technology has also been used in the treatment of rectal cancer at LUMC since May 2025
Other hospitals, such as the HagaZiekenhuis and HMC, are showing interest in LUMC's AI models and are working on applications for lung and prostate cancer.
Working together, these models can be tested and implemented faster
- Source 2:
LUMC integrates AI into radiotherapy planning, enhancing efficiency and patient safety
Supporting excerpts (6)
Leiden University Medical Center (LUMC) has successfully implemented artificial intelligence (AI) to optimize radiotherapy planning for patients with head and neck cancer.
This is a meticulous process requiring high precision, especially when tumors are adjacent to sensitive structures like salivary glands and swallowing muscles.
automates the delineation of healthy organs, reducing the planning time by approximately 50%
The tumor itself continues to be outlined manually by radiotherapists to ensure accuracy.
The AI system, trained on thousands of previous treatment plans, provides initial proposals for radiation dosing.
Radiation technologists then review and fine-tune these plans
- Source 3:
Deep Learning Autoplanning in Photon Beam Radiotherapy for Head and Neck Cancer
Supporting excerpts (41)
The research is conducted in collaboration with the radiotherapy department of the Leiden University
Dr. ir. F. Dankers, LUMC
chosen for clinical implementation at the LUMC
all patient cohorts demonstrate higher Planning Target Volume (PTV) coverage in the
However, DLAP show a significantly higher dose in the brain stem core for larynx
Furthermore, an increased dose is observed in the mandible across all patient cohorts.
particularly the contra-lateral salivary glands and swallowing muscles.
The NTCP analysis does not reveal notable improvements or worsening across all patient cohorts.
the need for further investigation in unilateral oropharynx cases, as DLAP did not sufficiently spare the
The divergence in treatment technique suggests waiting for a specifically trained
The first and largest cohort includes 43
intensive task, which can take up to half a day or even longer for a single patient with HNC.
treatment planning by RTTs also has the drawback of resulting in inconsistent treatment plans
generating a treatment plan is done in approximately fifteen minutes
dataset from the Princess Margaret Cancer Center in Toronto, Canada
structures and dose distribution of hundred previously treated bilateral
Number of plans 100 Origin Princess Margaret Cancer center
Training completion date 18 September 2021
the DLAP is validated with ten other patients by RaySearch
As input DLAP requires the CT image of the patient and segmentation of regions of interest (ROI).
Thirty ROIs (both target and OAR) are involved in autoplanning and twenty-two of them are required
The output of the DLAP is a predicted 3D dose distribution. The predicted dose is generated by a
convolutional neural network, specifically a U-Net.
creates a plan and deliverable dose by mimicking the predicted dose in a way that it is deliverable to
The predicted dose is mimicked by minimizing the difference
In practice there is a variation in treatment planning between different radiotherapy
provides the ability to have an institution specific DLAP model by tuning the initial model to the
In the LUMC such institution specific model is available, which is created in col-
RaySearch tunes the model with a few treatment
plans of patients previous treated at the LUMC.
the involved medical staff of the LUMC by evaluating the DLAP plans of thirteen patients according to
is submitted to the technical support of RaySearch and they start a new tuning round.
final tuning is conducted and approved by the medical staff, the DLAP can be used for automatically
all patient information and the clinical plans are anonymized prior to generating DLAP plans.
The DLAP used in this study is primarily trained on treatment plans that involve
DLAP cannot generate a plan when one of the required ROIs is missing.
the sparing of the swallowing muscles caused a local underdosage in
The DLAP that is proposed in the thesis does still need a work around, i.e. the extra local 2 mm
margin of the PTV in medial direction at level of the swallowing muscles. The expansion can be au-
Treatment planning will obviously keeps needing the professional opinion from a radiation oncolo-
gist and clinical physicist before administrating the dose to a patient.
Comments
Start the conversation.