UMC Utrecht cuts extra prostate biopsy stains with Paige AI
UMC Utrecht's uropathologists read digital prostate biopsy slides with Paige AI tumor marks on screen, to learn whether they could order fewer costly immunohistochemistry stains.
UMC UtrechtNetherlandsHospitals and health systemsPilot since Apr 2023
- Scale
- 82 patients in the CONFIDENT-P trial, then 130 cases at two Dutch hospitals
- Scenario
- AI-assisted cancer detection in prostate biopsies
- Business function
- Clinical care
- Kind of solution
- Visual inspection and monitoring
- Who built it
- Vendor product (Paige and Sectra)
- Human oversight
- Assists people
- Organization
- Academic or research
- AI types
- Computer vision
- Users
- two
- Sites
- two
tl;drAI-assisted pathologists ordered fewer extra stains and saved €1,700 on stains in the trial.See the results
UMC Utrecht’s pathology department uses Paige Prostate AI on digital prostate biopsy slides in prospective studies in daily diagnostics2, 1. Its uropathologists see the AI’s tumor marks in their first look at each slide3.
The hospital tested whether AI help lets pathologists order fewer immunohistochemistry (IHC) stains. IHC is an extra stain that the lab used on every prostate biopsy6. The test ran as the CONFIDENT-P trial, with Paige as the technology partner2, 5.
In the trial, AI-assisted pathologists used fewer IHC stains per detected cancer and saved €1,700 on stains2. In April 2026, a second study at two Dutch hospitals found that AI help changed the grade group in 16.5% of tumor entries1.
Before the deployment
UMC Utrecht’s pathology lab already worked digitally. In early 2016, it became the first hospital in the Netherlands to digitize its entire pathology workflow7. Pathologists read whole-slide images in the Sectra Digital Pathology Solution7.
The process had cost and consistency problems:
- H&E slides: Pathologists diagnose prostate cancer on hematoxylin and eosin (H&E) stained sections of needle biopsies2.
- IHC on every case: The lab performed IHC routinely on all prostate biopsies to confirm the diagnosis4.
- Cost: IHC is expensive, and its costs sometimes exceeded the reimbursement for the entire specimen3. One stain cost €502.
- Grading: Earlier work from Utrecht found large variability in Gleason scoring of prostate biopsies across the Netherlands5.
- Workload: Rising demand for care and a lack of specialists increased the pathologists’ workload3.
The team asked whether AI could find cancer cells on the H&E slide alone, so that fewer IHC stains would be needed3.
What was built
The AI reads each scanned H&E slide of a prostate biopsy and marks where it suspects cancer. The pathologist sees that output in the image viewer at the first assessment of the case3. The AI suggests, and the pathologist decides:
- Paige Prostate Suite: Detects tumor on the slide and calculates the tumor volume percentage. Its algorithms are CE-IVD certified3.
- Sectra pathology PACS: Displays the algorithms’ output graphically on the slide images that the pathologist reads3.
- Uropathologists: Evaluate every case and make the diagnosis. They can request an extra IHC stain whenever they need one3.
- IHC safety net: If the pathologist sees no tumor on the H&E slide, the lab still performs IHC, so that no tumor is missed3.
Before the prospective deployment, UMC Utrecht and Paige validated the software and the pathologists and aligned with data governance requirements5. The team started with tumor detection, because the routine workflow already had an objective reference standard in the pathologist and IHC3.
“Having acquired the first-ever FDA clearance for a clinical AI application in pathology, Paige Prostate Detect has cleared the highest bar for quality, and this provides us with confidence as we introduce it into live patient reporting.”
Rollout
CONFIDENT-P switched the AI on and off for alternating periods of one or two weeks, because the uropathologists work weekly schedules3. The 2025 study then used the AI for Gleason grading at two Dutch hospitals1.
Technology and architecture
The scanners feed the AI and the viewer at the same time. The AI analysis runs right after scanning, so that it adds no delay to the clinical workflow3.
| Layer | What they used | Role | Source |
|---|---|---|---|
| Vision model | Paige Prostate Detect | Marks the areas of each H&E slide that are suspicious for cancer | 2, 3, 5 |
| Vision model | Paige Prostate Grade & Quantify | Grades the cancer and calculates the tumor volume percentage | 3, 6 |
| Review workbench | Sectra pathology PACS | Shows the slides with the algorithms’ output displayed graphically | 3, 7 |
| Cameras and imaging | Hamamatsu S360 scanners | Digitize every glass slide into a whole-slide image | 3 |
The Paige algorithms are based on a weakly supervised deep learning algorithm3. The suite also includes an application for perineural invasion5.
Data inputs
- H&E whole-slide images: Each prostate needle biopsy slide is scanned at 40x. The scan is checked for color, focus quality, and completeness, and rescanned when necessary3.
- IHC-stained slides: The pathologist’s reading of the IHC slides is the reference standard for cases in doubt or judged benign4.
- Structured pathology reports: The trial took its baseline and outcome data from these reports3.
Integrations
The Paige algorithms are integrated within the Sectra PACS, which displays their output on the slide3. The integration was underway in November 20227. Paige never accesses the trial data or the patient files3.
How one biopsy flows through the system
- The lab stains the biopsy section with H&E. A Hamamatsu S360 scanner digitizes the slide at 40x3.
- The lab checks the scan for color, focus, and completeness, and rescans the slide when necessary3.
- Paige Prostate Detect analyzes the whole-slide image right after scanning3, 2.
- The Sectra PACS shows the slide with the AI output. The uropathologist reads both in the first assessment3.
- If the pathologist sees no tumor, the lab performs IHC with P503S, p63, and CK HMW3.
- The pathologist can also request IHC on any other slide to reach an adequate diagnosis3.
- The pathologist makes the diagnosis and records it in the structured pathology report3.
Results
CONFIDENT-P ran on 82 patients and 237 slides. Cancer was found in 64 patients and on 143 slides2. The grading study, published in April 2026, covered 283 entries from 130 consecutive cases at two Dutch hospitals1.
| Metric | Before | After | Scope and timeframe | Reported by |
|---|---|---|---|---|
| IHC stain costs saved | Not disclosed | €1,700 | CONFIDENT-P trial, 82 patients | UMC Utrecht researchers, pilot2 |
| Relative risk of IHC use per detected cancer, patient level | Control arm | 0.55 | CONFIDENT-P trial | UMC Utrecht researchers, pilot2 |
| Relative risk of IHC use per detected cancer, slide level | Control arm | 0.41 | CONFIDENT-P trial, 237 slides | UMC Utrecht researchers, pilot2 |
| Pathologists confident or highly confident | 56% | 80% | CONFIDENT-P trial | UMC Utrecht researchers, pilot2 |
| Median assessment time per H&E slide | 112 seconds | 139 seconds | CONFIDENT-P trial, no significant difference | UMC Utrecht researchers, pilot2 |
| Tumor entries with a changed grade group | Not disclosed | 16.5% | Two Dutch hospitals, January to June 2025 | UMC Utrecht researchers, pilot1 |
| Tumor detection agreement with and without AI | Not disclosed | 98.6% | 283 entries, January to June 2025 | UMC Utrecht researchers, pilot1 |
- Relative risk of IHC use: Compares the AI arm with the control arm in the chance that a detected cancer needed an IHC stain. A value below 1 means the AI arm used IHC less often2.
- Cost saved: The €1,700 covers the whole trial, at €50 per stain2.
- Confidence: The share of diagnoses that pathologists rated as confident or highly confident, with AI against without it2.
- Grade group changes: Each entry was graded by a pathologist without AI as the reference, then by the AI, then by the pathologist with AI. Of the 30 changed grades, 80.0% moved by one point and 20.0% by two points1.
- Tumor detection agreement: The pathologists with and without AI agreed on 279 of 283 entries. The differences were all low-grade GG1 tumors, which typically don’t need active treatment1.
Lessons learned
AI help cut IHC use on the cases where it could. The CONFIDENT-P authors conclude that it reduces IHC costs while keeping diagnostic safety standards, which supports the business case for AI in prostate cancer detection2.
The saving has a fixed limit. The lab still requested IHC for every slide on which no tumor was seen, so AI spared stains only where cancer was visible on the H&E slide2, 3. That safety net is also what let the trial run in daily practice without putting patients at risk3.
AI assistance didn’t make reading faster. The median time per slide showed no significant difference between the arms2, although faster case review was one of the aims that Paige set out for the study6.
The grading study measured influence, not accuracy. Its reference standard was the same pathologist’s grade without AI, and 36.7% of the changed grades were shifts between GG1 and GG2, which the authors call clinically relevant1. The authors see AI as a possible way to more accurate patient management1.
The figures are UMC Utrecht’s own, from studies its researchers ran and published1, 2. CONFIDENT was a single-center, non-randomized trial without blinding, with two expert urological pathologists4. Paige co-funded it, and the head of pathology sits on the scientific advisory boards of Paige and Sectra4, 3.
Case study scorecard
- €1,700 IHC stain costs saved in the CONFIDENT-P trial2
- 0.55 Relative risk of IHC use per detected cancer case, patient level2
- 80% Pathologists confident or highly confident in their diagnosis with AI2
- 16.5% Tumor entries whose grade group changed with AI assistance1
- Source quality: 72%, High quality. Rests on a peer-reviewed paper.
- Rules and standards: Medical device rules
Sources by publication date
- Organization 3
- Vendors and partners 2
- Press, academic, and regulators 4
Build this solution yourself
Analysis
What you need
- A fully digital pathology lab: The AI reads whole-slide images right after scanning, so you need scanners and image storage in routine use first. UMC Utrecht had worked digitally since 20167, 3.
- AI output inside the viewer that pathologists already use: The marks appear in the Sectra PACS at the first assessment, so the pathologist doesn’t switch tools3.
- A safety net with a reference standard: IHC on every negative slide protected patients and gave the trial its comparison. Check that your workflow has one before you change who confirms a tumor3.
Reference architecture
Visual inspection and monitoring
A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.
- Cameras and imaging (documented in this case study)
- Field network
- Device or line-side computer
- Privacy masking
- Vision model (documented in this case study)
- Inspection platform
- Thresholds and routing rules
- Risk or priority model
- Line or equipment controller
- Business or operational system
- Alert console
- Review screen (documented in this case study)
- Notifications
- Image and results store
- Verdict capture
- Model training environment
A check mark shows a building block that this case study's sources document.
Open the reference architectureOthers who built it
In the library
- Renault scales AI visual inspection to 500 checks per plant Renault Group
- AI return audits catch item swaps at Happy Returns Happy Returns
- Walmart tracks pallets with Wiliot IoT sensors and AI Walmart
- Van de Velde sizes bras from two smartphone photos with AI Van de Velde
- Synthetic boards train Siemens' inspection AI at Erlangen Siemens
- AI progress monitoring cuts rework on Intel's fab builds Intel
Cite this case study
Enterprise AI Case Studies. "UMC Utrecht cuts extra prostate biopsy stains with Paige AI." Updated Nov 21, 2026. https://case-studies.ai/case-studies/production-and-quality/PQ-036-prostate-biopsy-ai-detection-umc-utrecht/
@misc{csai-pq-036,
author = {{Enterprise AI Case Studies}},
title = {{UMC Utrecht cuts extra prostate biopsy stains with Paige AI}},
year = {2026},
note = {Updated 2026-11-21},
url = {https://case-studies.ai/case-studies/production-and-quality/PQ-036-prostate-biopsy-ai-detection-umc-utrecht/}
}Sources
The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership
- Source 1:
Supporting excerpts (12)
Between January and June 2025, diagnostic prostate biopsies from 130 consecutive cases with suspected prostate cancer were assessed at two Dutch hospitals.
Each biopsy entry was reviewed by one of three uropathologists in three sequential steps: (1) pathologist without AI (reference standard), (2) AI (Paige Prostate Suite), and (3) pathologist with AI assistance.
Tumor was found in 64.3% (182/283) of entries, with all GG observed.
GG assessments differed in 16.5% (30/182) of entries when comparing AI-assisted with unassisted evaluations.
Of these, 80.0% (24/30) involved a one-point change in GG, and 20.0% (6/30) involved a two-point change.
Notably, 36.7% (11/30) of discrepancies reflected a shift between GG1 and GG2.
Tumor detection agreement was 98.6% (279/283), with differences limited to GG1 tumors.
Uropathologists' confidence in Gleason grading increased from confident to high confidence.
GG changes were one or two points, with clinically relevant shifts between GG1 and GG2 in 36.7%.
Differences in tumor detection were limited to low-grade (GG1) cases, which typically do not require active treatment.
AI assistance may be a powerful tool to ensure more accurate patient management in prostate cancer.
Published - Apr 2026
- Source 2:
Supporting excerpts (11)
Some laboratories use costly immunohistochemistry (IHC) for all cases to optimize workflow, often exceeding reimbursement for the full specimen.
Patients suspected of PCa were allocated biweekly to either a control or intervention arm.
In the intervention arm, pathologists used the Paige Prostate Detect AI algorithm on HE slides, requesting IHC only as needed.
IHC was requested for all morphologically negative slides in the AI arm.
Overall, 143 of 237 (60.3%) slides of 64 of 82 patients contained PCa (78.0%).
AI assistance significantly reduced the risk of IHC use per detected PCa case at both the patient level (RR, 0.55; 95% CI, 0.39 to 0.72) and slide level (RR, 0.41; 95% CI, 0.29 to 0.52).
Cost reductions on IHC were €1,700 for the trial, at €50 per IHC stain.
AI-assisted pathologists reported higher confidence in their diagnoses (80% v 56% confident or high confidence).
The median assessment time per HE slide showed no significant difference between the AI-assisted and control arms (139 seconds v 112 seconds; P = .2).
This study demonstrates that AI assistance for PCa detection in PBx significantly reduces IHC costs while maintaining diagnostic safety standards, supporting the business case for AI implementation in PCa detection.
Published - Mar 2025
- Source 3:
Supporting excerpts (27)
As a pathology laboratory with a fully digital workflow for over 7 years, we are eager to explore the full potential of working digitally by adding the benefit of AI in daily pathology practice.
We decided to start with the object localisation task of tumour detection, where an objective reference standard is in place in the routine clinical workflow (ie, pathologist supervision and/or immunohistochemistry (IHC) staining).
However, IHC is expensive and these costs sometimes even exceed reimbursement for the entire specimen
This raises the question whether AI may be of added value to morphologically detect cancer cells without the need for IHC use.
Due to demographic trends, the needs for healthcare are increasing globally, which combined with a lack of specialists, increases the current workload.
where all slides are digitised using ultrafast whole slide image (WSI) using Hamamatsu S360 scanners and reviewed using the Sectra pathology Picture Archiving and Communication System (PACS).
Therefore, using AI every other week or every other 2 weeks, as opposed to switching by day, ensures that all pathologists are equally distributed between groups.
Lastly, it would be impractical to switch from AI assistance in the intervention group to no AI assistance in the control group on a case-to-case basis.
In the intervention group, pathologists will assess the H&E specimens digitally with the outcome of the algorithm provided in their first assessment of the specimen.
For PCa, they will use the CE-IVD certified Paige Prostate Suite algorithms for tumour detection and tumour volume percentage calculations
which are based on a weakly supervised deep learning algorithm
These algorithms will be integrated within the Sectra PACS where the output of the algorithms will be graphically displayed.
AI analysis of the WSI will be performed right after scanning to avoid delays in the clinical workflow.
If the AI-assisted pathologist does not detect metastases or tumours on the H&E slide, routine additional IHC staining will be performed by P503S/p63/CK HMW for PCa and CAM5.2 for BCa, to ensure no metastases or tumours are missed.
Pathologists can also request an additional IHC if they feel they need this to make an adequate diagnosis
Input data for the algorithm will be WSI of H&E stained slides scanned at 40× of either prostate needle biopsies
WSI will be quality controlled after scanning for colour, focus quality and completeness of the scan. When necessary, the specimens are rescanned.
As a rule in augmented intelligence, all cases will be evaluated by a pathologist
All data (baseline and primary outcome measurements) will be retrieved from the structured pathology reports
At no point will the data (both in Castor EDC and patient files) be accessed by the companies providing the algorithms (ie, Visiopharm and Paige).
Data access in Castor will be restricted to two researchers (RNF and CvD).
Informed consent was waived by the local quality coordinator and data protection officer
Therefore, the ethics committee (MREC NedMec) waived the need of ethical approval and informed consent.
However, the algorithms used are IVDR approved, and thus have undergone extensive review for their intended purpose.
Competing interests: PJvD is a member of the scientific advisory board of Paige and Sectra.
this trial serves as a template for other pragmatic AI-intervention trials for object-localisation tasks as well.
for the following reasons. First, in both arms, patients receive standard care, while maintaining diagnostic safety standards
- Source 4:
Supporting excerpts (11)
Single-center interventional non-randomized trial
For obvious reasons, allocation concealment and blinding of pathologists and researchers is not applicable.
two expert urological pathologists for the prostate needle biopsies
For prostate biopsies, IHC is routinely performed on all cases.
If no tumor can be seen, we will perform the additional immunohistochemistry, so no tumors will be missed.
These slides are always performed in cases where the pathologist is in doubt, or where they think the slides are benign.
Pathologists can always request an additional IHC-stain if they feel they need this to make an adequate diagnosis.
measured on a 5-Likert scale during the primary WSI assessment.
Date of first enrolment 19/09/2022
Completion date 31/12/2023
Who is funding the study? The Hanarth fund (Netherlands) Paige (USA)
- Source 5:
Supporting excerpts (7)
today announced it has entered into a multi-stage research agreement with the University Medical Center (UMC) Utrecht in the Netherlands.
UMC Utrecht will deploy Paige AI applications for routine clinical use and conduct a clinical health economics study to support the adoption and reimbursement of AI applications in pathology.
UMC Utrecht and Paige have already begun validation of the software and pathologist validation in addition to aligning with data governance requirements to enable prospective deployment.
is comprised of Paige Prostate Detect, Paige Prostate Grade & Quantify, and Paige Prostate Perineural Invasion.
Specifically, this collaboration builds on pioneering work from Utrecht which demonstrated large systemic variability in Gleason scoring of prostate biopsies nationwide in the Netherlands.
Having acquired the first-ever FDA clearance for a clinical AI application in pathology, Paige Prostate Detect has cleared the highest bar for quality, and this provides us with confidence as we introduce it into live patient reporting.
Professor and Head of Pathology at UMC Utrecht and a member of the Scientific Advisory Board at Paige
- Source 6:
Examining the Impact of AI on Pathology: A Deep-Dive into the CONFIDENT-P Study
Supporting excerpts (8)
The first study, called the CONFIDENT-Prostate study, is set to begin this month.
The study will take place over the course of 9 months, during which time 90 prostate cancer patients will be enrolled.
This suite of products includes Paige Prostate Detect, Paige Prostate Grade and Quantify, and Paige Prostate PNI, which work to help pathologists identify, grade and quantify prostate cancers, as well as identify the presence of perineurial invasion (PNI).
This is a common testing method at many institutions and is used upfront by UMC Utrecht on every prostate cancer biopsy.
speeding up case review time, more patients would reap the benefits of prompt turnaround times.
fewer new pathologists are entering the workspace
As the UMC Utrecht aims to be not only a development site, but also an implementation site for AI, we are thrilled to start this study with Paige.
The aim of the CONFIDENT-P study is to assess how pathologists, the diagnostic workflow, and the laboratory as a whole can benefit from AI-assisted pathology
- Source 7:
Netherlands Hospital to Deploy AI-Assisted Prostate Cancer Diagnostics Suite
Supporting excerpts (3)
In early 2016, UMC Utrecht became the first hospital in the Netherlands to digitize its entire pathology workflow.
UMC Utrecht currently employs the Sectra Digital Pathology Solution, a vendor-neutral solution for primary diagnostics in its pathology operations.
Integration of Paige applications with the Sectra solution is currently underway
- Source 8:
Study shows AI can be safely deployed in NHS prostate cancer diagnosis
Supporting excerpts (2)
The technology, Paige Prostate, was evaluated in the prostate cancer biopsy pathway across three NHS trusts in the UK.
The Articulate Pro study is one of the first examples of real-time use of AI technology in NHS histopathology practice.
- Source 9:
Labo Anatomopathologie maakt gebruik van diagnostische AI
Supporting excerpts (2)
werken met de Israëlische firma Ibex
Momenteel worden de prostaatbiopten in een validatiefase dubbel geanalyseerd, door AI en een patholoog.
Comments
Start the conversation.
Invited members of the library comment here. Sign in to join the conversation.