    Isala runs seven Aidoc radiology AI modules around the clock

    Isala, a large non-academic hospital in Zwolle, runs Aidoc's AI on CT scans day and night to flag bleeds, fractures, pulmonary embolisms and strokes for radiologists and emergency teams.

    IsalaNetherlands (Zwolle and Meppel)Hospitals and health systemsIn production since 2020
    Scale
    Seven AI modules, available 24/7
    Scenario
    Radiology triage and incidental finding detection
    Business function
    Clinical care
    Who built it
    Vendor product (Aidoc, UMC Utrecht, and Amsterdam UMC)
    Human oversight
    Assists people
    Organization
    Non-profit
    AI types
    Computer vision
    Users
    More than 50

    Sources and their publishers

    This case study draws on reporting by the following publishers. Enterprise AI Case Studies combined these accounts and added its own explanation. The reporting, and every passage quoted from it, belongs to whoever published or supplied it.

    1. Nederlandse Vereniging voor Radiologie

    2. Springer

    3. Aidoc

    4. Skipr

    tl;drIn a review of 3,316 Isala scans, AI found 96.8% of pulmonary embolisms, against 91.6% for reports.See the results

    View the solutionBuild this solution yourself

    Isala, a large non-academic hospital in Zwolle, runs seven Aidoc AI modules that analyze CT scans 24/7 and flag suspected acute findings for its clinicians1, 3.

    The modules detect pulmonary embolisms, brain bleeds, cervical spine fractures and strokes, and they’re integrated with the hospital’s PACS and structured reporting1. A mobile app alerts the stroke team and, since January 2026, the pulmonary embolism response team5, 6.

    In a review of 3,316 CTPA scans, the AI found 96.8% of acute pulmonary embolisms, against 91.6% for the original radiology reports2. In March 2026, Isala’s radiologists described how the AI has also led to a 24/7 agreement with the emergency department on which trauma patients need no radiologist consult1.

    Before the deployment

    Before the AI, one radiologist or radiology resident read and reported each Isala CT scan, a single time2. No algorithm supported the search for pulmonary embolisms2.

    • Workload: The radiologists face workload growth of 5% a year1. On-call CT scans rose 500% between 2006 and 2020 in a study the team cites2.
    • Trauma scans: After a head injury, a CT scan is often made to rule out bleeding or fractures4.

    “Imaging volumes continue to rise. Therefore, we need a clear plan on how AI technology can support radiologists to manage the increasing workload.”

    Martijn Boomsma, radiologist at Isala3

    What was built

    The solution sends each CT scan to Aidoc’s algorithms, which mark suspected findings in the images and notify the radiologist and, for strokes and embolisms, the treating team4, 6. Aidoc asked Isala in 2019 to be its reference site for radiology AI in the Netherlands, and Isala picked Aidoc for its own product portfolio and its own AI orchestrator, which avoids dependence on PACS or hardware vendors1.

    • AI modules: Detect intracranial bleeds, cervical spine fractures, and acute and incidental pulmonary embolisms. The stroke suite also assesses CT perfusion and finds vessel occlusions and brain aneurysms1.
    • Orchestrator and PACS: Connect the modules to PACS and to structured reporting, so the analysis sits where the radiologist reads and reports1.
    • Mobile app: Alerts the intervention team and shows the CT images on the phones of radiologists, interventional radiologists, neurologists and nurses, who talk by chat or phone4.
    • Radiologists: Stay responsible for the final diagnosis and the report, with Aidoc as a support tool1, 4.
    • Emergency doctors: Under a 24/7 service level agreement, they don’t consult the radiologist for selected low-energy trauma patients with no acute Aidoc findings and a fitting clinical picture1.

    Rollout

    Figure 1From reference site to seven modules
    From reference site to seven modulesIn 2019, Aidoc asked Isala to be its Dutch reference site. By mid-2020, three modules worked: intracranial bleeds, cervical spine fractures and acute pulmonary embolism. In 2024, the stroke app was officially taken into use. In January 2026, the pulmonary embolism response team solution went live.20192019 · Aidoc asks Isala to be reference site · Documented in source [1]Aidoc asks Isala to be reference site20202020 · Three modules working · Documented in source [1]Three modules working20242024 · Stroke app officially in use · Documented in source [4]Stroke app officially in useJan 2026Jan 2026 · Embolism response team goes live · Documented in source [6]Embolism response team goes liveFrom reference site to seven modulesIn 2019, Aidoc asked Isala to be its Dutch reference site. By mid-2020, three modules worked: intracranial bleeds, cervical spine fractures and acute pulmonary embolism. In 2024, the stroke app was officially taken into use. In January 2026, the pulmonary embolism response team solution went live.20192019 · Aidoc asks Isala to be reference site · Documented in source [1]Aidoc asks Isala tobe reference site1 yr20202020 · Three modules working · Documented in source [1]Three modulesworking4 yrs20242024 · Stroke app officially in use · Documented in source [4]Stroke appofficially in use2 yrsJan 2026Jan 2026 · Embolism response team goes live · Documented in source [6]Embolism responseteam goes live
    • Key milestone
    Sources [1][4][6]
    Isala went from three modules in 2020 to stroke and embolism team alerts by 2026.

    After the first three modules, Isala reviewed their accuracy, workflow impact and radiologist satisfaction, and then signed a strategic partnership with Aidoc that includes research1. The PERT solution was the first of its kind to go live in the Netherlands6.

    Technology and architecture

    Figure 2How Isala's CT scans reach the AI and the clinicians
    How Isala's CT scans reach the AI and the cliniciansCT scans go to Sectra PACS and to the Aidoc AI servers. The Aidoc AI orchestrator routes each scan to the AI modules. The modules return their findings to PACS, where the radiologist reads them, and the orchestrator writes results into structured reporting. For strokes and embolisms, the Aidoc app alerts the treating team. For selected trauma patients with no acute findings, the emergency doctor proceeds without a radiologist consult.CT scans (data) · Documented in source [4]CT studies (data) · Documented in sources [2] [1]scans to analyze (trigger or control) · Documented in source [1]flagged findings in PACS (handoff to people) · Documented in sources [1] [2]AI results (data) · Documented in source [1]stroke and PE alerts (data) · Documented in sources [5] [6]images and chat (handoff to people) · Documented in sources [5] [6]no acute findings (handoff to people) · Documented in source [1]final report (data) · Documented in source [4]ISALA SYSTEMSAIDOC PLATFORMISALA CLINICIANSCT scanner · Device · Documented in source [4]DEVICECT scannerSectra PACS · System · Documented in source [2]SYSTEMSectra PACSAidoc AI orchestrator · System · Documented in source [1]SYSTEMAidoc AIorchestratorAidoc AI modules · AI model · Documented in source [1]AI MODELAidoc AImodulesAidoc app · Application · Documented in sources [4] [5]APPLICATIONAidoc appRadiologist · Person · Documented in sources [1] [4]PERSONRadiologistStructured reporting · Application · Documented in source [1]APPLICATIONStructuredreportingStroke and PERT teams · Team · Documented in sources [5] [6]TEAMStroke andPERT teamsEmergency doctor · Person · Documented in source [1]PERSONEmergencydoctorCT scansCT studiesscans toanalyzeflaggedfindingsin PACSAI resultsstroke andPE alertsimagesand chatno acutefindingsfinal reportHow Isala's CT scans reach the AI and the cliniciansCT scans go to Sectra PACS and to the Aidoc AI servers. The Aidoc AI orchestrator routes each scan to the AI modules. The modules return their findings to PACS, where the radiologist reads them, and the orchestrator writes results into structured reporting. For strokes and embolisms, the Aidoc app alerts the treating team. For selected trauma patients with no acute findings, the emergency doctor proceeds without a radiologist consult.CT scans (data) · Documented in source [4]CT studies (data) · Documented in sources [2] [1]scans to analyze (trigger or control) · Documented in source [1]flagged findings in PACS (handoff to people) · Documented in sources [1] [2]AI results (data) · Documented in source [1]stroke and PE alerts (data) · Documented in sources [5] [6]images and chat (handoff to people) · Documented in sources [5] [6]no acute findings (handoff to people) · Documented in source [1]final report (data) · Documented in source [4]ISALA SYSTEMSAIDOC PLATFORMISALA CLINICIANSCT scanner · Device · Documented in source [4]DEVICECT scannerSectra PACS · System · Documented in source [2]SYSTEMSectra PACSAidoc AI orchestrator · System · Documented in source [1]SYSTEMAidoc AI orchestratorAidoc AI modules · AI model · Documented in source [1]AI MODELAidoc AI modulesAidoc app · Application · Documented in sources [4] [5]APPLICATIONAidoc appRadiologist · Person · Documented in sources [1] [4]PERSONRadiologistStructured reporting · Application · Documented in source [1]APPLICATIONStructured reportingStroke and PERT teams · Team · Documented in sources [5] [6]TEAMStroke and PERT teamsEmergency doctor · Person · Documented in source [1]PERSONEmergency doctorCT scansCT studiesscans to analyzeflagged findings in PACSAI resultsstroke and PE alertsimages and chatno acute findingsfinal report
    • AI component
    • Data
    • Trigger or control
    • Handoff to people
    Sources [1][2][4][5][6]
    Every CT goes to the AI and the radiologist at once, and flagged strokes and embolisms also reach the treating team's phones.

    The AI modules are image models that Aidoc builds and certifies. In this deployment, they read every relevant CT scan as it arrives4, 6. The embolism algorithm is CE-certified and FDA-approved, and it wasn’t trained on Isala’s data2.

    Layer What they used Role Source
    Vision model Aidoc pulmonary embolism algorithm Detects acute pulmonary embolism on CTPA and incidental embolism on routine chest CT 2, 1
    Vision model Aidoc stroke suite Analyzes brain CT for bleeds, vessel occlusions and aneurysms, and assesses CT perfusion 1, 5
    Vision model Hemorrhage and cervical spine fracture modules Flag intracranial hemorrhage and cervical spine fractures on CT 1, 3
    Vision model Aidoc PERT module Flags pulmonary embolism, calculates the RV/LV ratio and alerts the embolism response team 6, 1
    Workflow engine Aidoc AI orchestrator Connects the modules to PACS and structured reporting 1
    Model hosting Aidoc AI servers Receive each CT scan and run the algorithms, on a virtual machine integrated with PACS 4, 2
    Mobile or field app Aidoc app Alerts the stroke and embolism teams and shows CT images and chat on their phones 4, 5, 6
    Business or operational system Sectra PACS Holds the CT studies and shows the AI analysis to the radiologist 2, 1
    Workplace application Structured reporting Takes the AI results into the radiologist’s report 1

    Data inputs

    • CT scans: CTPA, routine chest, brain, perfusion and cervical spine CT, sent straight to the radiologist’s workstation and to the Aidoc AI servers1, 4.
    • Patient information: Goes with each stroke notification to the treatment team, together with the images5.

    Integrations

    • Sectra PACS: The algorithm runs on a virtual machine integrated with PACS and returns activation maps with possible findings2. The analysis reaches PACS on average in under 10 minutes1.
    • Structured reporting: The AI modules are integrated with structured reporting through the orchestrator1.
    • Aidoc app: Carries the alert, the images, patient data, the automated RV/LV ratio and a secure chat to the response team6.

    How one stroke scan flows through the system

    1. The CT scanner sends the brain scan to the radiologist’s workstation and to the Aidoc AI servers4.
    2. The Aidoc stroke suite checks the scan for bleeds, vessel occlusions and aneurysms, and assesses blood flow. The analysis usually takes under three minutes5.
    3. If it flags an abnormality, the Aidoc app alerts the whole intervention team with images and patient information4, 5.
    4. Neurologists and interventional radiologists consult each other in the app, by chat or phone4, 5.
    5. The clinicians review the full original study on a diagnostic viewer5.
    6. The radiologist makes the final diagnosis and writes the report4.

    Results

    Isala’s radiologists tested the modules on the hospital’s own scans, and the embolism and stroke modules now run in routine care1, 6.

    Metric Before After Scope and timeframe Reported by
    Acute pulmonary embolism sensitivity on CTPA 91.6% 96.8% 3,316 CTPA scans, 2018 to 2020, retrospective Isala researchers, in Insights into Imaging, measured2, 1
    Incidental pulmonary embolism sensitivity 62.7% 95.5% 3,089 routine chest CT scans, retrospective Isala researchers, measured1
    Suspected vessel occlusions prioritized Not disclosed 125 915 brain CT scans, six months to May 2026 Aidoc, measured5
    Rise in hospital costs, radiologist with AI Not disclosed 0.3% Cervical spine fractures, 2,368 patients Isala researchers, estimate1
    • Acute pulmonary embolism: Sensitivity is the share of real embolisms found. On 3,316 consecutive CTPA scans from 2018 to 2020, the reports missed 60 embolisms and the AI missed 232.
    • Incidental pulmonary embolism: On 3,089 routine chest CT scans, a considerable share of embolisms was seen only by the AI and not mentioned in the original report1.
    • Stroke triage: Over the six months before May 2026, the stroke suite analyzed 915 scans, prioritized 125 suspected vessel occlusions and found 21 more on scans not made for stroke5. More than 50 physicians use it5.
    • Fracture costs: The 0.3% is an estimate from an early health technology assessment of cervical spine fracture detection. In the radiologist-with-AI scenario, correct diagnoses rose and undertreatment fell1.
    • Emergency department flow: The 24/7 agreement with the emergency department speeds up patient flow, above all outside office hours1.
    • Embolism response team: More than 70 clinicians in radiology, interventional radiology, cardiology and critical care use the PERT solution in routine care since January 20266.

    Radiologists’ appreciation of the AI and their trust in its accuracy and workflow integration rose between surveys in 2021 and 2024, and they felt supported by it, above all on call1.

    Lessons learned

    The embolism results rest on a large, consecutive sample with an adjudicated reference standard. Two readers reviewed every case where the report and the AI disagreed2. The AI missed only peripheral embolisms and flagged two false positives, against nine in the reports2.

    Isala’s own researchers draw the line at support, not replacement. Standalone AI reading of CTPA isn’t warranted, because a model built for embolisms misses other relevant findings2.

    The cervical spine fracture module was weaker than the radiologists on its own, with 71.5% sensitivity against 88.2% on 2,368 patients1. Its value lies in catching the fractures a radiologist misses, when both read together1.

    False alarms remain a cost. For incidental embolisms, 85.3% of the AI’s positive calls were correct, against 95.5% for the reports, and radiologists named false positives and incidental findings as points to improve1.

    The start was slow. Bureaucracy and integration complexity meant only three modules worked by mid-2020, and the team says the AI still needs attention to automation bias, a solid IT infrastructure, periodic re-evaluation and monitoring for model drift1.

    The accuracy and cost figures are Isala’s own retrospective studies, partly with UMC Utrecht and Amsterdam UMC, and Aidoc partly funded the cost assessment1. The stroke and PERT figures are Aidoc’s5, 6. The team says the actual clinical effect still needs further study1. The sources also date the start differently: 2020 in Skipr and in Isala’s own account, 2021 in Aidoc’s4, 5.

    Case study scorecard

    Build this solution yourself

    Analysis

    What you need

    • A PACS and reporting chain the AI can reach: The orchestrator connects the modules to Sectra PACS and structured reporting, and that integration took Isala until mid-2020 for three modules1, 2.
    • Your own scans to test on: Isala checked each module against its own radiology reports on thousands of scans before it relied on them1, 2.
    • A written rule with the emergency department: You need an agreement that says which patients the emergency doctor can treat on a negative AI result, because the radiologist stays responsible for the read1.
    • On-call specialists who use the app: The stroke and embolism alerts only speed up care when the teams act on them from their phones5, 6.

    Reference architecture

    Visual inspection and monitoring

    A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.

    A check mark shows a building block that this case study's sources document.

    Open the reference architecture

    Others who built it

    Cite this case study

    Enterprise AI Case Studies. "Isala runs seven Aidoc radiology AI modules around the clock." Updated Nov 26, 2026. https://case-studies.ai/case-studies/production-and-quality/PQ-051-radiology-ai-triage-isala/

    @misc{csai-pq-051,
      author = {{Enterprise AI Case Studies}},
      title = {{Isala runs seven Aidoc radiology AI modules around the clock}},
      year = {2026},
      note = {Updated 2026-11-26},
      url = {https://case-studies.ai/case-studies/production-and-quality/PQ-051-radiology-ai-triage-isala/}
    }

    Sources

    The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership

    1. Source 1:

      Aidoc altijd aan in het Isala

      OrganizationNederlandse Vereniging voor Radiologie, Mar 2, 20262 Mar 2026By Ingrid Nijholt, Rogier van Dijk, and Martijn BoomsmaDocumentIn DutchAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (43)
      • n 2019 vroeg Aidoc Isala om als re
      • wikkelde productportfolio en de eigen AI-orkestrator, waarmee afhankelijk
      • heid van PACS- of hardwareleveranciers werd vermeden.
      • Pas medio 2020 waren, door bureaucratie en integratiecomplexiteit, drie modules functioneel
      • niële bloedingen, cervicale wervelfrac
      • turen op CT en acute longembolieën op CTPA
      • Hierbij zijn accuratesse, de impact op de workflow en radiologentevreden
      • zijn Isala en Aidoc een strategisch part
      • met het UMC Utrecht en het Amsterdam UMC
      • Momenteel draaien in Isala zeven AI
      • modules van Aidoc die 24/7 beschikbaar zijn. Deze zijn geïntegreerd met PACS en gestructureerde verslaglegging
      • stroke-suite. Deze ondersteunt onder andere CT-perfusie en het opsporen van vaatocclusies en hersenaneurysma
      • ook als mobiele applicatie beschikbaar, zodat zij de beeldvorming ook op afstand direct kunnen inzien.
      • Het opsporen van acute longembolieën is retrospectief geanalyseerd op 3.316 CTPA-scans.
      • Sensitiviteit in % (95%-BI) 91,6 (89,6 - 93,7) 96,8 (95,5 - 98,1) < 0,001
      • Bij 3.089 portoveneuze CT-thoraxscans verbeterde AI aantoonbaar de detectie van incidentele longembolieën.
      • Sensitiviteit in % (95%-BI) 62,7 (51,1- 74,3) 95,5 (90,6 - 100,0) < 0,001
      • Positief voorspellende waarde in % (95%-BI) 95,5 (89,3 - 100,0) 85,3 (77,3 - 93,3) 0,047
      • In een aanzienlijk deel van de gevallen werd een longembolie alleen door AI gezien en niet in het oorspronkelijke verslag ver
      • spectraal detector CT-scans van 114 patiënten
      • de niet significant tussen virtuele mono
      • wel continue monitoring van algoritmen om modeldrift te detecteren belangrijk blijft
      • spectieve cohortstudie met 2.368 pati
      • De diagnostische accuratesse van de radiologen was weliswaar iets hoger dan die van de AI, maar in een scenario waarbij radioloog en AI samen zouden worden gebruikt
      • Sensitiviteit in % (95%-BI) 88,2% (84,0 - 92,5) 71,5% (65,5 - 77,4) < 0,001
      • dat deze AI sterk is als ondersteuning van de radioloog door gemiste fracturen van de radioloog te detecteren
      • een early health technology assessment verricht met onder andere een onder
      • zoeksbeurs van Aidoc.
      • totale kostentoename in het ziekenhuis beperkt tot 0,3 procent, terwijl het aantal correcte diagnoses steeg
      • tes (2021 en 2024) onder ongeveer twin
      • namen de waardering en het vertrouwen in nauwkeurigheid en workflowintegratie toe.
      • Radiologen gaven aan zich duidelijk gesteund te voelen door de aanwezigheid van AI, met name in de dienst.
      • commentaren werden foutpositieven
      • en incidentele bevindingen als punten van verbetering genoemd
      • in PACS met gemiddeld < 10 minuten klinisch acceptabel te vinden, zeker bij acute pathologie.
      • een 24/7 Service Level Agreement (SLA) met de SEH, waarin is vastgelegd dat bij geselecteerde laagenergetische trau
      • mapatiënten, zonder acute bevindingen volgens Aidoc en passend bij de kliniek, de SEH-arts de radioloog niet hoeft te consulteren
      • name buiten kantoortijden de patiënten
      • antwoordelijkheid van de radioloog, met Aidoc als ondersteunend hulpmiddel.
      • kwaliteitsvraag van 5 procent jaarlijkse werkdrukgroei.
      • blijvende aandacht voor automation bias, een robuuste IT-infrastructuur en perio
      • dels meer op gebruikerscomfort dan op validatie en uitgebreide kosteneffectivi
      • De daadwerkelijke klinische effectiviteit moet nog nader worden on
    2. Source 2:

      Retrospective batch analysis to evaluate the diagnostic accuracy of a clinically deployed AI algorithm for the detection of acute pulmonary embolism on CTPA

      AcademicSpringer, Jun 6, 20236 Jun 2023By Eline Langius-WiffenAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (18)
      • Consecutive CTPA scan data of 3316 patients referred because of suspected PE between 24-2-2018 and 31-12-2020 were retrospectively analysed by a CE-certified and FDA-approved AI algorithm.
      • PE was present in 717 patients (21.6%)
      • PE was missed by the AI in 23 patients, while the attending radiologist missed 60 PE. The AI detected 2 false positives and the attending radiologist 9.
      • The sensitivity for the detection of PE by the AI algorithm was significantly higher compared to the radiology report (96.8% vs. 91.6%, p < 0.001). Specificity of the AI was also significantly higher (99.9% vs. 99.7%, p = 0.035).
      • Discordant cases were independently reviewed by a chest radiologist
      • The algorithm was deployed on a virtual machine and integrated with our PACS (SECTRA).
      • where after we received AI activation maps that provided possible PE findings
      • Aidoc Medical was not involved in study design or analysis of the AI output they provided.
      • Their algorithm has not been trained on data originating from our hospital.
      • In our hospital, CT scans are reviewed and reported just once by either a radiologist or by a radiology resident
      • During the study period, there was no algorithmic support for PE detection in usage.
      • CT scans during on-call hours were reported to have increased with 500% between 2006 and 2020
      • Solely peripheral PE were missed by the AI algorithm (7 segmental, 16 subsegmental).
      • to detect a single additional acute PE case would require a number-needed-to-analyse by AI of 56 patients
      • However, standalone use of AI algorithms in reading CTPA is currently not warranted
      • current algorithms focused on the detection of PE will miss other relevant findings
      • Highest diagnostic accuracy can likely be achieved by radiologists supported by AI.
      • The Department of Radiology, Isala, has established a strategic partnership with Aidoc Medical. However, this study was not part of this partnership.
    3. Source 3:

      Isala Signs Strategic Agreement with Aidoc to Harness the Combined Potential of Radiologists and AI

      Partner or vendorAidoc, Dec 9, 20249 Dec 2024By Ariella ShohamAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (5)
      • one of the largest non-academic medical facilities in the Netherlands
      • AI algorithms for triage and notification of intracranial hemorrhage (ICH), pulmonary embolism (PE), and c-spine fractures
      • Imaging volumes continue to rise. Therefore, we need a clear plan on how AI technology can support radiologists to manage the increasing workload.
      • AI offers us a high degree of comfort amid periods of both higher and lower imaging volumes, and especially during night shifts.
      • algorithm for c-spine fractures on a validated database of 2,331 CT scans and showed the potential value of the AI as a concurrent reader by increasing the total number of fractures identified by a radiologist by 13% (ECR 2022 oral presentation)
    4. Source 4:

      Isala-specialisten stellen met AI-app sneller diagnose beroerte

      IndependentSkipr, Oct 9, 20249 Oct 2024By Skipr RedactieIn DutchAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (11)
      • Voor de AI-ondersteuning werkt Isala sinds 2020 samen met het bedrijf AIDOC.
      • Dat geeft 24/7 AI-ondersteuning bij het beoordelen van CT-scans van de hersenen op bloedingen, doorbloedingsproblemen en andere afwijkingen.
      • Radiologen en neurologen hebben de AI-app van AIDOC onlangs officieel in gebruik genomen.
      • Bij een hoofdtrauma wordt bijvoorbeeld vaak een CT-scan gemaakt om bloedingen of breuken uit te sluiten.
      • CT-scans worden direct naar ons werkstation en naar de AI-servers van AIDOC gestuurd.
      • Binnen 5 tot 10 minuten krijgen we een melding of er afwijkingen zijn, zoals fracturen of bloedingen.
      • AI markeert deze afwijkingen duidelijk in de beelden.
      • Als radioloog blijven we natuurlijk altijd verantwoordelijk voor de uiteindelijke diagnose en verslaglegging.
      • Met de AIDOC-app wordt het hele interventieteam direct gealarmeerd.
      • De CT-beelden zijn veilig zichtbaar op mobiele apparaten voor radiologen, interventieradiologen, neurologen en verpleegkundigen.
      • Ze kunnen direct communiceren via chat of telefoon over de behandeling.
    5. Source 5:

      AI in Stroke Care: Faster Action and Better Collaboration

      Partner or vendorAidoc, May 21, 202621 May 2026By Nicola EmeryAccessed Nov 26, 202626 Nov 2026

      Supporting excerpts (11)
      • they have been at the forefront of using AI in radiology since 2021
      • which is fully integrated into the stroke care pathway
      • If abnormalities are flagged, the treatment team receives an immediate notification including images and relevant patient information.
      • Specialists such as neurologists and interventional radiologists can consult with each other directly via a secure app.
      • This prompts clinicians to quickly review the full, original study on a diagnostic viewer
      • Over the past six months, the AI has analysed 915 scans, which has led to the prioritisation of 125 suspected cases of vascular occlusion.
      • Additionally, suspected blocked blood vessels were identified in 21 cases where scans were not specifically performed for stroke assessment.
      • Analyses are performed very quickly, usually within three minutes of the scan being taken, allowing for faster triage.
      • More than 50 physicians at Isala are now actively using the AI.
      • Thanks to the app, we can see acute cases on our phones earlier
      • AI has proven its value within our hospital.
    6. Source 6:

      Isala Hospital Leads the Way with First AI-Powered Pulmonary Embolism Response in the Netherlands

      Partner or vendorAidoc, Mar 16, 202616 Mar 2026Accessed Nov 26, 202626 Nov 2026

      Supporting excerpts (10)
      • In January this year, Isala Hospital became the first health system in the Netherlands to go live with an AI-powered Pulmonary Embolism Response Team (PERT) solution.
      • More than 70 clinicians across radiology, interventional radiology, cardiology, and critical care now use the AI-powered PERT solution as part of routine clinical care at Isala.
      • Running continuously in the background, the AI analyses all relevant CT scans for suspected pulmonary embolism, flagging positive cases directly to radiologists and automatically alerting the wider PERT team via a mobile app when high-risk patients are identified.
      • such as the automated calculation of the right ventricle-to-left ventricle (RV/LV) ratio
      • together with a secure chat function, enable rapid, real-time interdisciplinary decision-making
      • currently being conducted across 14 major Dutch teaching hospitals
      • new AI-powered PERT workflow will help identify more eligible patients for the trial.
      • CE marked by Imbio Inc. CE 2797
      • With AI in our PERT workflow, we identify high-risk patients faster and initiate the right treatment more quickly,
      • AI increases our visibility and accelerates coordination, which strengthens both patient care and research.

    More in Production & Quality