Choose your region

    Lists show the case studies of your region first. Browse and search still hold every case study.

    Europe
    North America

    Catharina Ziekenhuis cuts fracture consults 70% with AI

    The Eindhoven hospital pairs an AI reading of each fracture X-ray with the radiographer's own, so radiographers call a radiologist only when they're in doubt or the two disagree.

    Catharina ZiekenhuisNetherlands (Eindhoven)Hospitals and health systemsIn production since Feb 2025
    Scenario
    Fracture and abnormality detection on X-rays
    Business function
    Clinical care
    Who built it
    Vendor product (VZVZ, Radiobotics, and Alphatron Zorgverbinders)
    Where it runs
    Vendor-hosted service
    Human oversight
    Assists people
    Organization
    Non-profit
    AI types
    Computer vision
    Sites
    5

    Sources and their publishers

    This case study draws on reporting by the following publishers. Enterprise AI Case Studies combined these accounts and added its own explanation. The reporting, and every passage quoted from it, belongs to whoever published or supplied it.

    1. ICT&health

    2. AIFI

    3. NVvR

    tl;drRadiographers' direct radiologist consultations fell 70% after AI joined fracture X-ray checks.See the results

    View the solutionBuild this solution yourself

    Catharina Ziekenhuis in Eindhoven uses AI to assess X-rays of patients with a possible fracture1. Radiographers combine the AI reading with their own, and they call a radiologist only when they’re in doubt or the two disagree1.

    The hospital went live with AI in radiology in February 2025, as one of five hospitals in AIFI, a shared Dutch AI infrastructure for radiology4. AIFI contracted RBfracture from Radiobotics for fracture detection2, 7.

    In October 2026, the hospital reported that radiographers’ direct consultations with radiologists fell by 70%1.

    Before the deployment

    Before the change, radiographers regularly called in a radiologist for a quick assessment of an X-ray1. Each call interrupted the radiologist, for example during another examination1.

    • Out-of-hours delays: Outside regular office hours, a radiologist could take longer to become available for an interim assessment1.
    • Growing demand: Demand for radiology examinations grew faster than the capacity of radiologists, radiographers, and equipment2.
    • Barriers to AI: Hospitals struggled with costs, limited IT capacity, integration with existing systems, and a lack of clinical validation2.

    In 2023, VZVZ and the Dutch Society of Radiology (NVvR) started AIFI to tackle these barriers together, with funding from Zorgverzekeraars Nederland (ZN)3, 2. The project picked five hospitals from 15 applicants, Catharina among them7, 2.

    What was built

    The solution gives each X-ray of a possible fracture an AI reading as soon as it’s taken, so the radiographer can make the first assessment without a direct call to a radiologist1.

    • AI tool: Analyzes each X-ray directly after it’s taken and indicates whether there are signs of a fracture1.
    • AIFI infrastructure: Sends the images from the hospital to a central cloud environment, where the AI models run, and returns the results to the hospital’s picture archiving and communication system (PACS)2, 3.
    • Radiographers: Combine the AI outcome with their own assessment. If the two agree, the image doesn’t need a direct discussion with a radiologist in certain situations1.
    • Radiologists: Advise when the radiographer is in doubt or the assessments differ. They stay responsible for the final assessment and report every X-ray afterwards1.

    The AI has a supporting role and takes no independent medical decisions1. Radiologist Dennis Kies and technical physician Daphne Hinssen worked on the implementation, with the focus on how the tool supports daily work rather than on the algorithm alone1.

    Rollout

    Figure 1From a joint tender to a reported result
    From a joint tender to a reported resultAIFI sent its request for proposal to AI vendors in July 2024. The five pilot hospitals, Catharina Ziekenhuis included, were live on February 17, 2025. The first pilot phase ended on July 1, 2025, and the pilot was extended by a year. AIFI announced national scale-up on May 20, 2026. Catharina reported 70% fewer direct radiologist consultations on October 9, 2026.Jul 2024Jul 2024 · AIFI sends request for proposal to AI vendors · Documented in source [8]AIFI sends request forproposal to AI vendors17 Feb 202517 Feb 2025 · Five pilot hospitals live, Catharina included · Documented in source [4]Five pilot hospitals live,Catharina included1 Jul 20251 Jul 2025 · First pilot phase ends, pilot extended a year · Documented in source [5]First pilot phase ends,pilot extended a year20 May 202620 May 2026 · AIFI announces national scale-up · Documented in source [6]AIFI announces national scale-up9 Oct 20269 Oct 2026 · Catharina reports 70% fewer consultations · Documented in source [1]Catharina reports 70%fewer consultationsFrom a joint tender to a reported resultAIFI sent its request for proposal to AI vendors in July 2024. The five pilot hospitals, Catharina Ziekenhuis included, were live on February 17, 2025. The first pilot phase ended on July 1, 2025, and the pilot was extended by a year. AIFI announced national scale-up on May 20, 2026. Catharina reported 70% fewer direct radiologist consultations on October 9, 2026.Jul 2024Jul 2024 · AIFI sends request for proposal to AI vendors · Documented in source [8]AIFI sends request forproposal to AI vendors7 mo17 Feb 202517 Feb 2025 · Five pilot hospitals live, Catharina included · Documented in source [4]Five pilot hospitals live,Catharina included5 mo1 Jul 20251 Jul 2025 · First pilot phase ends, pilot extended a year · Documented in source [5]First pilot phase ends,pilot extended a year10 mo20 May 202620 May 2026 · AIFI announces national scale-up · Documented in source [6]AIFI announcesnational scale-up5 mo9 Oct 20269 Oct 2026 · Catharina reports 70% fewer consultations · Documented in source [1]Catharina reports 70%fewer consultations
    • Key milestone
    Sources [1][4][5][6][8]
    Catharina went live in the AIFI pilot in February 2025 and reported its result in October 2026.

    Catharina stayed among the four active hospitals when the pilot was extended to June 30, 2026, and AIFI is now scaling up nationally5, 2, 6. Fracture detection is now the starting point for new AI projects in Catharina’s radiology department1.

    Technology and architecture

    Figure 2How a fracture X-ray gets its AI reading at Catharina
    How a fracture X-ray gets its AI reading at CatharinaAn X-ray of a possible fracture leaves the hospital through a local gateway as pseudonymized images. In the AIFI central cloud, the fracture detection AI analyzes the images and sends its result back to the hospital's PACS. The radiographer combines the AI outcome with their own assessment and hands the case to a radiologist when in doubt or when the two disagree. The radiologist makes the final assessment and records it in the radiology report. No part of the figure is inferred.pseudonymized images (data) · Documented in source [3]images (data) · Documented in source [2]AI result (data) · Documented in source [3]AI outcome (data) · Documented in sources [1] [3]doubt or disagreement (handoff to people) · Documented in source [1]final assessment (data) · Documented in source [1]CATHARINA ZIEKENHUISAIFI CENTRAL CLOUDX-ray of possible fracture · Data · Documented in source [1]DATAX-ray ofpossiblefractureLocal gateway · System · Documented in source [2]SYSTEMLocal gatewayFracture detection AI · AI model · Documented in sources [1] [2]AI MODELFracturedetection AIPACS · System · Documented in source [3]SYSTEMPACSRadiographer · Person · Documented in source [1]PERSONRadiographerRadiologist · Person · Documented in source [1]PERSONRadiologistRadiology report · Data · Documented in source [1]DATARadiologyreportpseudonymizedimagesimagesAI resultAI outcomedoubt ordisagreementfinalassessmentHow a fracture X-ray gets its AI reading at CatharinaAn X-ray of a possible fracture leaves the hospital through a local gateway as pseudonymized images. In the AIFI central cloud, the fracture detection AI analyzes the images and sends its result back to the hospital's PACS. The radiographer combines the AI outcome with their own assessment and hands the case to a radiologist when in doubt or when the two disagree. The radiologist makes the final assessment and records it in the radiology report. No part of the figure is inferred.pseudonymized images (data) · Documented in source [3]images (data) · Documented in source [2]AI result (data) · Documented in source [3]AI outcome (data) · Documented in sources [1] [3]doubt or disagreement (handoff to people) · Documented in source [1]final assessment (data) · Documented in source [1]CATHARINA ZIEKENHUISAIFI CENTRAL CLOUDX-ray of possible fracture · Data · Documented in source [1]DATAX-ray ofpossible fractureLocal gateway · System · Documented in source [2]SYSTEMLocal gatewayFracture detection AI · AI model · Documented in sources [1] [2]AI MODELFracture detection AIPACS · System · Documented in source [3]SYSTEMPACSRadiographer · Person · Documented in source [1]PERSONRadiographerRadiologist · Person · Documented in source [1]PERSONRadiologistRadiology report · Data · Documented in source [1]DATARadiology reportpseudonymized imagesimagesAI resultAI outcomedoubt or disagreementfinal assessment
    • AI component
    • Data
    • Handoff to people
    Sources [1][2][3]
    The AI reading goes to the radiographer first, and a radiologist steps in on doubt and reports every image.
    Layer What they used Role Source
    Vision model RBfracture Fracture detection product from Radiobotics, contracted by AIFI for its pilot hospitals 2, 7
    Model hosting Central cloud environment Hosts, monitors, and tests the AI models 2
    APIs and connectors Twiin Portal Existing national image exchange infrastructure that the AIFI setup is based on, run with Alphatron Zorgverbinders 2, 4
    APIs and connectors Local gateway Connects each hospital to the central cloud environment 2
    Privacy controls Pseudonymization Pseudonymizes the images before they go to the central platform 3, 4
    Monitoring Performance monitoring Tracks the performance of the AI solutions centrally 2
    Business or operational system PACS Shows the AI result to staff as a secondary capture 3

    The architecture is separate from the PACS, the electronic health record, and the AI vendor3. New algorithms can be added without reconfiguring the system, so hospitals keep their flexibility3.

    Data inputs

    • X-rays of possible fractures: The AI analyzes each image directly after it’s taken1. An urgent fracture request often has one or two images, where fast feedback matters3.
    • Sample images from vendors: During procurement, the clinical working group rated sample images from each vendor for clarity and ease of use, as a mini-validation8.

    Integrations

    • PACS: The AI results go back to the PACS in the hospital as a secondary capture. The applications are part of the PACS environment and of the regular care process3, 6.
    • Central cloud environment: The local gateway sends pseudonymized images and receives the results2, 3.

    How one X-ray flows through the system

    1. A radiographer takes an X-ray of a patient with a possible fracture1.
    2. The AI tool analyzes the image directly and indicates whether there are signs of a fracture1.
    3. The radiographer compares the AI outcome with their own assessment1.
    4. If both agree, the radiographer goes on without a direct discussion with a radiologist, in certain situations1.
    5. If the radiographer is in doubt or the assessments differ, the radiographer consults a radiologist1.
    6. A patient with a suspected fracture is referred to the plaster room sooner. A patient without signs of a fracture can be sent home sooner1.
    7. A radiologist officially assesses the X-ray afterwards and records it in a radiology report1.

    Results

    Metric Before After Scope and timeframe Reported by
    Direct consultations of a radiologist by radiographers Not disclosed 70% fewer Fracture X-rays at Catharina Ziekenhuis, reported in October 2026 Catharina Ziekenhuis, measured1
    Cases in which more than half of users applied RBfracture Not disclosed In at least 70% of cases Five AIFI pilot hospitals, first pilot phase to July 2025 AIFI, pilot2, 5
    • Direct consultations: Counts the moments when a radiographer has to consult a radiologist directly for a quick assessment. The hospital notices the benefit mostly outside regular office hours1.
    • RBfracture use: Measures how often users applied the tool, not its accuracy. The figure covers all five pilot hospitals, not Catharina alone2.
    • Implementation effort: The shared approach gave an estimated time saving of 34% compared with individual AI implementations2.
    • Availability: The AIFI infrastructure was available more than 99% of the time3.

    Lessons learned

    The gain came from changing the workflow, with the AI tool built into the existing care process1. The AIFI evaluation also found that RBfracture led to adjusted workflows in some hospitals, in which radiographers acted more independently and quickly2.

    Speed matters in acute work. Half of the surveyed radiographers found the processing times for fracture detection disruptive, although the times stayed within the required limits2.

    The shared infrastructure limits what staff can do with the result. The AI output appears in the PACS as a secondary capture, with no interaction in the viewer and no worklist prioritization through HL7 messages3.

    Legal work took longer than the technology. Legal alignment and governance needed significant time, and a change to the contract structure on legal advice delayed the project2, 8.

    The 70% figure is the hospital’s own, reported by ICT&health1. ICT&health adds that better diagnostic outcomes from such tools need a separate evaluation1. The AIFI evaluation states that the benefits of its AI applications rested largely on estimates from healthcare professionals rather than on objective measurements2.

    Case study scorecard

    • 70% Fewer direct consultations of a radiologist by radiographers1MeasuredRelayed
    • at least 70% Share of cases in which more than half of users applied RBfracture2PilotSelf-reported

    Build this solution yourself

    Analysis

    What you need

    • A rule for when radiographers act alone: You need an agreed rule for when the AI and the radiographer agree, when a radiologist is called, and who reports every image. The drop in consultations came from that rule1.
    • AI results fast enough for acute work: You need processing times that radiographers accept in urgent cases, because half of the surveyed radiographers in the AIFI hospitals found them disruptive2.
    • A local team across disciplines: You need radiologists, radiographers, IT, application management, and legal support together, because these teams set up the workflow and the technical links in each AIFI hospital3.

    Reference architecture

    Visual inspection and monitoring

    A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.

    A check mark shows a building block that this case study's sources document.

    Open the reference architecture

    Others who built it

    • Amphia Ziekenhuis in Breda has used BoneView on X-rays since early 2026, with a first indication in about two minutes1.
    • Ziekenhuis Rivierenland in Tiel took part in the AIFI pilot and kept using its infrastructure in the extension4, 5.
    • Ziekenhuisgroep Twente also kept using the AIFI infrastructure after the first pilot phase5.

    Cite this case study

    Enterprise AI Case Studies. "Catharina Ziekenhuis cuts fracture consults 70% with AI." Updated Nov 21, 2026. https://case-studies.ai/case-studies/production-and-quality/PQ-033-fracture-xray-triage-catharina/

    @misc{csai-pq-033,
      author = {{Enterprise AI Case Studies}},
      title = {{Catharina Ziekenhuis cuts fracture consults 70% with AI}},
      year = {2026},
      note = {Updated 2026-11-21},
      url = {https://case-studies.ai/case-studies/production-and-quality/PQ-033-fracture-xray-triage-catharina/}
    }

    Sources

    The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership

    1. Source 1:

      AI verkort wachttijden bij onderzoek naar botbreuken

      IndependentICT&health, Oct 9, 20269 Oct 2026In DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (26)
      • Het Catharina Ziekenhuis in Eindhoven zet kunstmatige intelligentie in om röntgenfoto's van patiënten met een mogelijke botbreuk sneller te beoordelen.
      • Door de AI-technologie te integreren in het bestaande zorgproces is het aantal momenten waarop laboranten direct een radioloog moeten raadplegen met 70 procent afgenomen.
      • Radioloog Dennis Kies en technisch geneeskundige Daphne Hinssen zijn binnen het Catharina Ziekenhuis betrokken bij de implementatie van AI op de afdeling Radiologie.
      • Daarbij ligt de nadruk niet uitsluitend op de prestaties van het algoritme, maar vooral op de manier waarop de technologie het dagelijkse werk kan ondersteunen.
      • De AI-tool analyseert röntgenfoto's direct nadat deze zijn gemaakt en geeft aan of er aanwijzingen zijn voor een botbreuk.
      • De uitkomst wordt vervolgens gecombineerd met de beoordeling van de laborant.
      • Wanneer beide beoordelingen overeenkomen, hoeft de foto in bepaalde situaties niet meer direct met een radioloog te worden besproken.
      • Bij twijfel of afwijkende beoordelingen wordt de radioloog wel geraadpleegd.
      • Volgens Hinssen heeft deze aangepaste werkwijze het aantal directe overlegmomenten met radiologen met 70 procent verminderd.
      • Voorheen moesten laboranten regelmatig een radioloog inschakelen voor een snelle beoordeling.
      • Dat leidde tot werkonderbrekingen, bijvoorbeeld wanneer een radioloog bezig was met ander onderzoek.
      • Door de eerste beoordeling anders te organiseren, kan de beschikbare radiologische expertise gerichter worden ingezet.
      • De radioloog blijft wel verantwoordelijk voor de definitieve beoordeling.
      • Alle röntgenfoto's worden achteraf officieel beoordeeld en vastgelegd in een radiologisch verslag.
      • Patiënten met een vermoedelijke botbreuk kunnen bijvoorbeeld sneller worden doorverwezen naar de gipskamer.
      • Wanneer er geen aanwijzingen voor een fractuur zijn, kan eerder worden besloten dat iemand naar huis mag.
      • Volgens het ziekenhuis zijn de voordelen vooral buiten reguliere kantooruren merkbaar.
      • Op die momenten kan het langer duren voordat een radioloog beschikbaar is voor een tussentijdse beoordeling.
      • Het Catharina Ziekenhuis benadrukt dat AI hierbij een ondersteunende rol heeft en geen zelfstandige medische beslissingen neemt.
      • Sinds begin 2026 werkt ook het Amphia Ziekenhuis in Breda met AI bij het beoordelen van röntgenfoto's.
      • Daar wordt het programma BoneView ingezet, dat binnen ongeveer twee minuten een eerste indicatie geeft.
      • De ervaringen in Eindhoven en Breda laten zien dat de waarde van AI in de radiologie niet alleen wordt bepaald door de nauwkeurigheid waarmee afwijkingen worden herkend.
      • Ook de integratie in bestaande werkprocessen speelt een belangrijke rol.
      • Bij het Catharina Ziekenhuis vormt de toepassing voor fractuurdetectie inmiddels een uitgangspunt voor nieuwe AI-projecten binnen Radiologie.
      • De gemelde vermindering van overlegmomenten laat zien dat aanpassing van de werkwijze meetbare voordelen kan opleveren.
      • Of dergelijke toepassingen ook leiden tot betere diagnostische uitkomsten, vraagt om afzonderlijke evaluatie.
    2. Source 2:

      Evaluation AIFI: Feasibility study for a national AI infrastructure for radiology in the Netherlands

      Partner or vendorAIFI, Aug 26, 202526 Aug 2025DocumentAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (20)
      • Catharina Ziekenhuis, Gelre Ziekenhuizen, Radboudumc, Ziekenhuisgroep Twente, and Ziekenhuis Rivierenland.
      • RBfracture (Radiobotics): for fracture detection
      • The demand for radiological examinations is growing faster than the capacity of radiolo gists, radiographers, and equipment.
      • hospitals often struggle with costs, limited IT capacity, integration into existing systems, and a lack of clinical validation.
      • AIFI is an initiative by VZVZ and NVvR, funded by ZN.
      • Five hospitals were selected based on diversity in institutional type, technical infrastructure (PACS and EHR systems), and maturity in AI adoption.
      • The technical infrastructure used during the pilot was based on the Twiin Portal.
      • Each participating hospital was equipped with a local gateway connected to a central cloud environment, where the AI models were hosted, monitored, and tested.
      • In the cloud environment, the AI solutions were centrally available and their performance was continuously monitored.
      • Implementation was phased, with the three AI solutions gradually rolled out across the five hospitals.
      • This led to an estimated time saving of 34% compared to individual AI implementations.
      • processing times, although within the required limits, were still perceived as disruptive by half of the surveyed radiographers.
      • The project also revealed that legal alignment and governance require significant time and effort.
      • hospitals only had to go through technical and legal processes once, saving both time and money.
      • the benefits of AI applications were largely based on estimates from healthcare professionals rather than on objective measurements.
      • The AI application for bone age prediction (BoneXpert) achieved high adoption rates (>90%)
      • The fracture detection application (RBfracture) was used by more than half of the users in at least 70% of cases and led to adjusted workflows in some hospitals, allowing radiographers to act more independently and quickly.
      • The evaluation highlights that the success of AI strongly depends on clinical context, integration, and ease of use.
      • The AIFI pilot has been extended until June 30, 2026. Four pilot hospitals will continue using the infrastructure
      • Costs per hospital decreased especially when multiple AI applications were used and multiple hospitals participated.
    3. Source 3:

      Van belofte naar praktijk: AIFI als vliegwiel voor landelijke AI-uitrol

      Partner or vendorNVvR, Sep 9, 20259 Sep 2025By Joost Nederend, Marieke Zimmerman, and Jan-Jaap VisserDocumentIn DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (18)
      • is in 2023 het landelijke AIFI-project gestart
      • waarmee beelden gepseudonimiseerd
      • worden gestuurd naar een centraal platform en verwerkt worden door het AI-algoritme en de AI-resultaten worden teruggestuurd naar het PACS
      • toegevoegd zonder herinrichting van het systeem
      • De architectuur staat los van PACS, EPD en AI-leverancier
      • ziekenhuizen maximale flexibiliteit behouden
      • interactie met de AI binnen de viewer
      • output wordt als secondary capture
      • zoals werklijstprioritering via HL7
      • uit één of twee röntgenopnamen, waar snelle terugkoppeling waardevol is
      • applicatiebeheer, (project)management en juridische ondersteuning
      • technische koppelingen, het verzorgen van de instructie
      • Een centrale stuurgroep bewaakt de projectvoortgang
      • ziekenhuizen lokaal eigenaar blijven van de implementatie
      • plaats via logdata, enquêtes en
      • een beschikbaarheid van meer dan 99%
      • les is dat lokale regie cruciaal is voor een succesvolle implementatie
      • radioloog Catharina Ziekenhuis en lid stuurgroep AIFI
    4. Source 4:

      AI in de praktijk: pilot in vijf Nederlandse ziekenhuizen van start gegaan

      Partner or vendorAIFI, Feb 17, 202517 Feb 2025DocumentIn DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (6)
      • Op 17 februari is de pilot van het project AI For Imaging (AIFI)
      • De vijf deelnemende ziekenhuizen zijn inmiddels live gegaan.
      • Gelre ziekenhuizen, Ziekenhuisgroep Twente en het Catharina Ziekenhuis.
      • in samenwerking met leverancier Alphatron Zorgverbinders, beschikbaar
      • worden gepseudonimiseerd verwerkt, zodat de
      • De gegevens zijn goed versleuteld en alleen toegankelijk voor professionals die ermee werken.
    5. Source 5:

      Informatie AIFI-project: projectupdate juli 2025

      Partner or vendorAIFI, Jul 28, 202528 Jul 2025DocumentIn DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (4)
      • De oplossingen worden momenteel klinisch gebruikt
      • Op 1 juli is de eerste fase van de haalbaarheidsstudie afgerond.
      • De AIFI-pilot wordt met een jaar verlengd
      • verlengingsperiode blijven vier pilotziekenhuizen actief, namelijk Ziekenhuis Rivierenland, Gelre ziekenhuizen, Ziekenhuisgroep Twente en Catharina Ziekenhuis.
    6. Source 6:

      AIFI maakt de sprong: van pilot naar landelijke opschaling

      Partner or vendorAIFI, May 20, 202620 May 2026In DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (2)
      • De pilot is positief geëvalueerd en nu vindt landelijke opschaling van AIFI plaats.
      • De toepassingen zijn geïntegreerd in de PACS-omgeving en onderdeel van het reguliere zorgproces
    7. Source 7:

      Informatie AIFI-project: projectupdate maart 2025

      Partner or vendorAIFI, Mar 20, 202520 Mar 2025DocumentIn DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (4)
      • Het projectteam heeft 5 ziekenhuizen gekozen uit 15 aanmeldingen voor deelname.
      • om uiteindelijk met één AI product per toepassingsgebied het project te doorlopen.
      • Radiobotics RBfracture (fractuurdetectie)
      • hebben er vele testen plaatsgevonden, waaronder acceptatietesten en retrospectieve testen.
    8. Source 8:

      Informatie AIFI-project: projectupdate oktober 2024

      Partner or vendorAIFI, Oct 16, 202416 Oct 2024DocumentIn DutchAccessed Nov 21, 202621 Nov 2026

      Supporting excerpts (7)
      • Eind juli is aan de AI-leveranciers een verzoek om offerte (request for proposal
      • In de RFP waren de verschillende algemene, technische, klinische en beveiligingseisen en wensen geformuleerd.
      • werd een aantal voorbeeld-beelden beoordeeld door de klinische werkgroep op duidelijkheid en gebruikersvriendelijkheid, als mini-validatie.
      • De aanbiedingen werden op al deze aspecten en de prijs zorgvuldig gescoord
      • Hier is uiteindelijk van afgeweken voor de contractstructuur, op advies van de juristen.
      • Dit heeft voor enige vertraging gezorgd in de voortgang van het project
      • een voorstel voor DPIA voor de ziekenhuizen

    More in Production & Quality

    View all