Choose your region

    Lists show the case studies of your region first. Browse and search still hold every case study.

    Europe
    North America

    AI triage cuts mammogram reading in Denmark's Capital Region

    The Capital Region of Denmark's breast screening programme lets Transpara sort screening mammograms, sending the likely normal ones to one radiologist instead of two.

    Capital Region of DenmarkDenmarkHospitals and health systemsIn production since Nov 2021
    Scale
    58,246 women screened with AI, November 2021 to October 2022
    Scenario
    Screening mammogram triage
    Business function
    Clinical care
    Who built it
    Vendor product (Human Bytes, University of Copenhagen, and Radboud University)
    Human oversight
    Assists people
    Organization
    Public sector
    AI types
    Computer vision
    Users
    19
    People served
    220.000
    Sites
    5

    Sources and their publishers

    This case study draws on reporting by the following publishers. Enterprise AI Case Studies combined these accounts and added its own explanation. The reporting, and every passage quoted from it, belongs to whoever published or supplied it.

    1. Radiological Society of North America

    2. Capital Mammography Screening Programme, conference slides hosted by Lægeforeningen

    3. The Lancet

    4. WellSpan Health

    5. Radiology: Artificial Intelligence

    6. Frontiers in Stroke

    7. U.S. Food and Drug Administration

    tl;drRadiologists did 33.5% fewer reads while the cancer detection rate rose from 0.70% to 0.82%.See the results

    View the solutionBuild this solution yourself

    The Capital Region of Denmark’s screening program has used Transpara, a commercial AI system, to triage screening mammograms since November 2021. The exams that Transpara rates as likely normal now go to one radiologist instead of two1, 4.

    By 2026, the program had moved to a newer version of the model, Transpara 2.1.0-B2.

    Researchers from the program and the University of Copenhagen compared the first year of triage with the year of double reading before it, in a study that Radiology published in June 2024. Across 60,751 women screened before the switch and 58,246 after it, radiologists did 33.5% fewer screening reads1, 3. The recall rate fell by 20.5%, and the cancer detection rate rose from 0.70% to 0.82%1, 3.

    Before the deployment

    Until November 2021, two breast radiologists read every screening mammogram in the Capital Region1, 4. The region invites women aged 50 to 69 to mammography screening every two years1. The old process worked as follows:

    • Screening: Radiographers take two views of each breast at one of five screening clinics. This takes 6 to 10 minutes in the examination room, with no clinical examination or ultrasound2.
    • Central reading: Two radiologists read each exam blind, each taking from under a minute to three minutes2.
    • Recalls: In the screening round just before AI, the region recalled 3.09% of the women it screened1.
    • Cost of a recall: The program counts one diagnostic workup, with its clinical examination, ultrasound, and sometimes a needle biopsy, as the equivalent of 30 to 50 single readings2.

    European guidelines recommend two readers, and double reading is standard practice in European screening programs6. Double reading exists to catch cancers and cut false-positive recalls, so each reader still has to go through every normal exam3. It improves accuracy, but it adds substantially to the workload and staffing problems of breast radiology4.

    “Population-based screening with mammography reduces breast cancer mortality, but it places a substantial workload on radiologists who must read a large number of mammograms, the majority of which don’t warrant a recall of the patient”

    Andreas D. Lauritzen, postdoctoral researcher at the University of Copenhagen3

    The program warns that even a small rise in the recall rate eats into the benefit of screening2. It therefore set a narrow goal for AI, to reduce radiologist workload while keeping the quality indicators stable2.

    What was built

    The AI decides how many radiologists read an exam, and radiologists decide everything else. Transpara analyzes each screening exam before a radiologist sees it2. The work is divided as follows:

    • Transpara: Gives regions of the images a local score. The highest regional score becomes the exam’s risk score, which appears at the end of the exam in PACS, the picture archiving system that radiologists read from2.
    • Single-read score cutoff: Uses the exam score to select each exam for single or double reading, based on the probability that breast cancer is present4. At launch, an exam qualified for single reading with an AI examination score of 5 or less. From May 3, 2022, the cutoff was 7 or less1.
    • Single-read path: For an exam rated likely normal, the AI counts as the first reader and one breast radiologist as the second. When the two disagree, the exam goes on a consensus list2. The single reads went to one of 19 senior full-time breast radiologists1.
    • Double-read path: An exam with an intermediate or high score gets the usual double blind reading by two breast radiologists, now with the AI’s help2. The AI marks the suspicious lesions on these women’s images4.
    • Radiologists: Make every recall decision. The AI has no direct recall2. Radiologists can also see each woman’s earlier mammograms, and the AI system can’t2, 3.

    Lauritzen, who led the evaluation, put the change in terms of where the radiologists’ time goes. “AI is not taking over the radiologists’ work,” he said. “Rather, it assists and reallocates their time to more pressing tasks”4.

    Alternatives considered

    Before going live, the program tested bolder protocols on its own history. The simulations used every consecutive screening exam from January 2014 to December 2015, with two years of follow-up2, 5. Two University of Copenhagen institutes, the program, and a professor from Radboud University in the Netherlands who founded the AI did the work together2, 5. The program considered the following protocols:

    • AI reading alone: In a preliminary simulation, the AI read alone, with its sensitivity set to match experienced breast radiologists. That removed all radiologist reading. Its specificity was lower than the radiologists’ (94.9% against 98.1%), and the number of women with a false-positive result would have risen from 2,107 to 5,8252.
    • Skip and recall on score: In the main simulation, exams scoring below 5 would skip radiologist reading, and the most suspicious would be recalled directly on a threshold fitted to match radiologist sensitivity. Two radiologists would read the rest. The AI-based screening’s sensitivity of 69.7% was noninferior to the radiologists’ 70.8%, workload fell by 62.6%, and 25.1% of false-positive screenings were avoided5.

    The protocol that the region put into service is more cautious than either, with at least one radiologist on every exam2.

    Rollout

    Procurement and implementation took three months, in a collaboration between CIMT, Human Bytes / Transpara, and clinical staff from the screening program2. The program went live on Transpara 1.7.0, which is CE and FDA approved2.

    Figure 1From double reading to routine AI triage
    From double reading to routine AI triageThe double-read comparison cohort began on October 1, 2020. AI triage went live on November 18, 2021. The single-read cutoff was raised from an AI examination score of 5 to 7 on May 3, 2022. The first-year comparison window closed on October 17, 2022. The results were published in Radiology on June 4, 2024. By 2026 the programme ran Transpara version 2.1.0-B.1 Oct 20201 Oct 2020 · Double-read comparison cohort begins · Documented in source [1]Double-read comparison cohort begins18 Nov 202118 Nov 2021 · AI triage goes live · Documented in source [1]AI triage goes live3 May 20223 May 2022 · Single-read cutoff raised from 5 to 7 · Documented in source [1]Single-read cutoff raised from 5 to 717 Oct 202217 Oct 2022 · First-year comparison window closes · Documented in source [1]First-year comparison window closes4 Jun 20244 Jun 2024 · Results published in Radiology · Documented in source [3]Results published in Radiology20262026 · Programme runs Transpara 2.1.0-B · Documented in source [2]Programme runs Transpara 2.1.0-BFrom double reading to routine AI triageThe double-read comparison cohort began on October 1, 2020. AI triage went live on November 18, 2021. The single-read cutoff was raised from an AI examination score of 5 to 7 on May 3, 2022. The first-year comparison window closed on October 17, 2022. The results were published in Radiology on June 4, 2024. By 2026 the programme ran Transpara version 2.1.0-B.1 Oct 20201 Oct 2020 · Double-read comparison cohort begins · Documented in source [1]Double-readcomparisoncohort begins1 yr 1 mo18 Nov 202118 Nov 2021 · AI triage goes live · Documented in source [1]AI triage goes live6 mo3 May 20223 May 2022 · Single-read cutoff raised from 5 to 7 · Documented in source [1]Single-read cutoffraised from 5 to 75 mo17 Oct 202217 Oct 2022 · First-year comparison window closes · Documented in source [1]First-year comparisonwindow closes1 yr 8 mo4 Jun 20244 Jun 2024 · Results published in Radiology · Documented in source [3]Results publishedin Radiology2 yrs20262026 · Programme runs Transpara 2.1.0-B · Documented in source [2]Programme runsTranspara 2.1.0-B
    • Key milestone
    Sources [1][2][3]
    The region raised the single-read cutoff less than six months after go-live and published its first-year results in 2024.

    Technology and architecture

    Figure 2How the Capital Region's AI triage fits into screening
    How the Capital Region's AI triage fits into screeningRadiographers at five screening clinics take two-view mammograms, which Transpara scores. The risk score is shown in PACS. The exam score is checked against a cutoff: low scores go to the AI as first reader plus one breast radiologist, higher scores to two radiologists who see the AI marks. Radiologists also see the woman's earlier mammograms, which the AI does not. Disagreements in the low-risk path go to a consensus list. Radiologists recall women for a diagnostic workup. How the consensus list leads to a recall is inferred.images (data) · Documented in source [2]risk score (data) · Documented in source [2]exam score (data) · Documented in sources [1] [2]likely normal (handoff to people) · Documented in source [1]higher score (handoff to people) · Documented in sources [1] [4]score shown (data) · Documented in source [2]previous exams (data) · Documented in sources [2] [3]disagreement (handoff to people) · Documented in source [2]recall (handoff to people) · Documented in source [2]recall (handoff to people) · Inferred, not documented in the sourcesrecall (handoff to people) · Documented in source [2]SCREENING CLINICSAI TRIAGECENTRAL READINGTwo-view mammogram · Device · Documented in source [2]DEVICETwo-viewmammogramTranspara · AI model · Documented in sources [2] [3]AI MODELTransparaExam score cutoff · Decision · Documented in sources [1] [4]DECISIONExam scorecutoffPACS · System · Documented in source [2]SYSTEMPACSEarlier mammograms · Data · Documented in sources [2] [3]DATAEarliermammogramsAI plus one radiologist · Team · Documented in sources [1] [2]TEAMAI plus oneradiologistConsensus list · Application · Documented in source [2]APPLICATIONConsensus listTwo radiologists, AI marks · Team · Documented in sources [2] [4]TEAMTworadiologists,AI marksDiagnostic workup · Step · Documented in source [2]Diagnosticworkupimagesrisk scoreexam scorelikely normalhigher scorescore shownprevious examsdisagreementrecallrecallrecallHow the Capital Region's AI triage fits into screeningRadiographers at five screening clinics take two-view mammograms, which Transpara scores. The risk score is shown in PACS. The exam score is checked against a cutoff: low scores go to the AI as first reader plus one breast radiologist, higher scores to two radiologists who see the AI marks. Radiologists also see the woman's earlier mammograms, which the AI does not. Disagreements in the low-risk path go to a consensus list. Radiologists recall women for a diagnostic workup. How the consensus list leads to a recall is inferred.images (data) · Documented in source [2]risk score (data) · Documented in source [2]exam score (data) · Documented in sources [1] [2]likely normal (handoff to people) · Documented in source [1]higher score (handoff to people) · Documented in sources [1] [4]score shown (data) · Documented in source [2]previous exams (data) · Documented in sources [2] [3]disagreement (handoff to people) · Documented in source [2]recall (handoff to people) · Documented in source [2]recall (handoff to people) · Inferred, not documented in the sourcesrecall (handoff to people) · Documented in source [2]SCREENING CLINICSAI TRIAGECENTRAL READINGTwo-view mammogram · Device · Documented in source [2]DEVICETwo-view mammogramTranspara · AI model · Documented in sources [2] [3]AI MODELTransparaExam score cutoff · Decision · Documented in sources [1] [4]DECISIONExam score cutoffPACS · System · Documented in source [2]SYSTEMPACSEarlier mammograms · Data · Documented in sources [2] [3]DATAEarlier mammogramsAI plus one radiologist · Team · Documented in sources [1] [2]TEAMAI plus one radiologistConsensus list · Application · Documented in source [2]APPLICATIONConsensus listTwo radiologists, AI marks · Team · Documented in sources [2] [4]TEAMTwo radiologists,AI marksDiagnostic workup · Step · Documented in source [2]Diagnostic workupimagesrisk scoreexam scorelikely normalhigher scorescore shownprevious examsdisagreementrecallrecallrecall
    • AI component
    • Data
    • Handoff to people
    • Inferred, not documented
    Sources [1][2][3][4]
    Transpara's score decides whether one or two radiologists read an exam; only radiologists decide on recall.

    One commercial model does the work, inside the reading system that the program already had. Transpara is made by ScreenPoint Medical and is intended as a concurrent reading aid10. It outputs the locations of calcifications and soft-tissue regions with scores for the likelihood that cancer is present, and an exam score for the whole exam10.

    The system that the region uses was trained with deep learning to highlight and rate suspicious lesions and calcifications3. Region scores run to 100, and the exam score runs to 103.

    The following table lists the components of the solution.

    Layer What they used Role Source
    Vision model Transpara version 2.1.0-B (version 1.7.0 at launch), from ScreenPoint Medical Scores each exam for the likelihood of cancer and marks suspicious regions 2, 3, 10
    Rules and decision logic Single-read score cutoff Sends exams scoring 7 or less (5 or less before May 3, 2022) to one radiologist, the rest to two 1, 4
    Business or operational system PACS Shows the AI risk score at the end of each exam 2
    Review workbench Consensus list Holds low-risk exams on which the AI first reader and the radiologist disagree 2

    Transpara’s output reaches radiologists in PACS2, and the score sends the exam down one of two reading paths4. A setup like this most likely applies the cutoff in the reading worklist, so that a single-read exam never appears for a second radiologist.

    Data inputs

    The solution uses the following data:

    • Screening exams: Each exam has two standardized views, CC and MLO2.
    • Training data: Transpara version 1.7.0 was trained on more than 1 million processed mammograms from different vendors in Europe and the USA. The region’s own screening data wasn’t part of that training2.
    • Biopsy and surgical outcomes: These confirmed the cancers in the before-and-after comparison, with at least 180 days of follow-up1.
    • National performance indicators: The Danish Quality Database for Mammography Screening is the yardstick for Danish screening as a whole. Its indicators cover recall, false-positive, and detection rates for every screening round from 2008 to 20202.

    How one exam flows through the system

    Two exams from the study show what the AI’s score does and doesn’t decide. In both, the high score bought the exam a second reader, and the radiologists made the call. The first exam went through the following steps:

    1. Transpara gave a 57-year-old woman’s exam an AI examination score of 10, driven by one lesion that it scored 89 out of 1003.
    2. Because of the high score, two radiologists read the exam. Both marked the same lesion as the AI, and she was recalled3.
    3. In the diagnostic workup, ultrasound showed a small invasive carcinoma of 4 by 7 millimeters3.

    A 67-year-old woman’s exam also scored 10, this time because of arterial calcifications that the AI rated 85 out of 100. It went to double reading for the same reason. The two radiologists judged that the calcifications didn’t suggest breast cancer, and she wasn’t recalled4.

    Results

    The study, published in Radiology in June 2024, compares women screened with AI from November 18, 2021, to October 17, 2022, with women double-read from October 1, 2020, to November 17, 2021. All were aged 50 to 69, and their cancers were confirmed by biopsy or surgery1, 3. All screening performance indicators improved except the node-negative rate, which didn’t change3.

    Metric Before After Scope and timeframe Reported by
    Screening reads by radiologists Every exam read twice 33.5% fewer reads Before and after cohorts, October 2020 to October 2022 Capital Region and University of Copenhagen researchers, measured1
    Recall rate 3.09% 2.46% Same cohorts, a 20.5% reduction Capital Region and University of Copenhagen researchers, measured1
    Cancer detection rate 0.70% 0.82% Same cohorts, at least 180 days of follow-up Capital Region and University of Copenhagen researchers, measured1
    False-positive rate 2.39% 1.63% Same cohorts Capital Region and University of Copenhagen researchers, measured1
    Positive predictive value of a recall 22.6% 33.6% Same cohorts Capital Region and University of Copenhagen researchers, measured1
    Small cancers (1 cm or less) 36.6% 44.9% Share of invasive cancers, same cohorts Capital Region and University of Copenhagen researchers, measured1
    Invasive share of cancers found 84.9% 79.6% Same cohorts Capital Region and University of Copenhagen researchers, measured1

    The metrics need the following explanations:

    • Screening reads: In the AI period, 66.9% of screenings were single-read and 33.1% were double-read with AI assistance3. Each single-read exam needs one read instead of two, which is where the 33.5% comes from1.
    • Positive predictive value: Measures how many recalled women turned out to have cancer. It rose from under a quarter to a third1.
    • Recall rate by path: In the program’s own running figures, which extend to December 31, 2022, the overall recall rate of 2.46% averages 0.40% in the low-risk group and 6.65% for women with intermediate or high scores. The AI acted as first reader on 67.41% of screenings2.
    • Recall rate and the cutoff: Raising the single-read cutoff came with a drop in the recall rate from 2.72% to 2.29%2.
    • Cancer detection rate: The rise works out to 12 more cancers per 10,000 women screened, and the invasive cancers found were smaller. Lauritzen said the smaller size “could possibly indicate earlier detection”4.

    The program sums up the early quality indicators as at least as good as before2.

    Lessons learned

    The triage was measured in routine service across a whole region, and the recall rate fell under a protocol more cautious than the simulations1, 2. Amie Y. Lee and Sarah M. Friedewald’s accompanying editorial called the study additional evidence that AI can help decrease workload while preserving, if not increasing, interpretive performance4.

    The same editorial urged caution. Recalling a 2006 study that found no gain in accuracy from computer-aided detection after decades of clinical use, they wrote: “Although modern AI systems based on convolutional neural networks are superior to conventional CAD, repeating the same mistakes must be avoided and a dose of skepticism is warranted,”4.

    Its first reason for caution is the 180-day minimum follow-up, which is too short to judge false negatives, the cancers a screening misses4. Its second is that more of the extra cancers were ductal carcinoma in situ, an early non-invasive form, so higher detection might not mean fewer interval cancers or better outcomes4. In 2026 the program still listed interval-cancer data as its next step2, and Lauritzen called for research on long-term outcomes and on whether overdiagnosis rises3.

    The AI has no previous images to compare with, and all 14 cancers among the 215 recalled low-risk women were new lesions or had changed since the last exam2, 3. “That’s something we’d like to work on in the future,” Lauritzen said3. The FDA device record for Transpara 2.1.0 describes that version as adding a comparison of the current exam with prior exams10.

    The model on its own wasn’t enough. In the preliminary simulation, the AI reading alone had lower specificity than the radiologists and produced far more false positives2. The live protocol keeps a radiologist on every exam, and the product’s own labeling says patient management decisions shouldn’t rest on Transpara alone10.

    Every figure comes from the program’s own researchers. The peer-reviewed paper’s authors include Ilse Vejborg, who heads the screening program1, 2, and the program names among its partners in the work a Radboud University professor who founded the AI2.

    The comparison isn’t a trial, and its two periods differ: the median screening interval was 993 days in the AI cohort against 845 days before1. A longer gap since the last screen would by itself be expected to raise the share of cancers found. Detection with AI was higher in each interval band, but significantly so only for 2.33 to 2.66 years, 0.96% against 0.64%2.

    A few figures differ across sources. The paper gives a 33.5% workload reduction and a positive predictive value of 33.6% against 22.6%1, where the journal’s press release gives 33.4% and 33.5% against 22.5%3. The paper counts 58,246 women screened with AI1, where the program’s slides list 56,894 screenings for the same dates2. Both count 60,751 screenings before AI1, 2, but the slides’ recall summary gives that round as “63.682 q”, women screened, with the same 3.09% recall rate2.

    Case study scorecard

    Build this solution yourself

    Analysis

    What you need

    To build this solution, you need the following in place:

    • Double reading to remove: The region already double-read every exam, so the AI could remove a second read rather than add a step1. A program that already single-reads would most likely not get the same saving.
    • A local history of exams with known outcomes: The region simulated the protocol on two full years of its own screenings before committing to one5. Lauritzen’s team noted that results depend on the reading protocol, the radiologists, and how they interact with the AI4, and US screening protocols differ from Denmark’s3.
    • Senior breast radiologists for the single read: A group of 19 senior full-time breast radiologists did the single reads1.

    Reference architecture

    Visual inspection and monitoring

    A visual inspection and monitoring solution uses a vision model to read images from cameras and find or measure defects, objects, events, or conditions that people or systems then act on. The vision model reads each image, and rules send each detection to a line controller, a business system, or a person. People confirm or correct the findings and tune the process from the measurements, and their verdicts and newly labeled images keep the model current.

    A check mark shows a building block that this case study's sources document.

    Open the reference architecture

    Others who built it

    • Lund University: The MASAI trial at four Swedish screening sites used AI to send low-risk exams to single reading and high-risk ones to double reading. It cut screen-reading workload by 44% in its interim results and interval cancers by 12% in its full results6.
    • WellSpan Health: The central Pennsylvania health system has used Aidoc for imaging triage since 20227.
    • UT Southwestern Medical Center: Reprioritizing the head CT worklist with AI cut the wait for exams flagged for intracranial hemorrhage from 15.75 to 12.01 minutes per study8.
    • TeleSpecialists: Across 166 facilities using Viz.ai, the time from a stroke patient’s arrival to notifying the interventionalist was 39.5 minutes faster than at facilities without the software9.

    Cite this case study

    Enterprise AI Case Studies. "AI triage cuts mammogram reading in Denmark's Capital Region." Updated Nov 19, 2026. https://case-studies.ai/case-studies/production-and-quality/PQ-008-medical-imaging-triage/

    @misc{csai-pq-008,
      author = {{Enterprise AI Case Studies}},
      title = {{AI triage cuts mammogram reading in Denmark's Capital Region}},
      year = {2026},
      note = {Updated 2026-11-19},
      url = {https://case-studies.ai/case-studies/production-and-quality/PQ-008-medical-imaging-triage/}
    }

    Sources

    The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership

    1. Source 1:

      Early Indicators of the Impact of Using AI in Mammography Screening for Breast Cancer

      AcademicRadiological Society of North America, Jun 4, 20244 Jun 2024By Andreas D. Lauritzen, Martin Lillholm, Elsebeth Lynge, Mads Nielsen, Nico Karssemeijer, and Ilse VejborgAccessed Nov 16, 202616 Nov 2026

      Supporting excerpts (25)
      • This retrospective study included 50-69-year-old women who underwent biennial mammography screening in the Capital Region of Denmark.
      • Before AI system implementation (October 1, 2020, to November 17, 2021), all screenings involved double reading.
      • For screenings conducted after AI system implementation (November 18, 2021, to October 17, 2022), likely normal screenings (AI examination score ≤5 before May 3, 2022, or ≤7 on or after May 3, 2022) were single read by one of 19 senior full-time breast radiologists.
      • The remaining screenings were read by two radiologists with AI-assisted decision support.
      • Biopsy and surgical outcomes were retrieved between October 1, 2020, and April 15, 2023, ensuring at least 180 days of follow-up.
      • Screening metrics were compared using the χ2 test.
      • Reading workload reduction was measured as saved screening reads.
      • with a median screening interval before AI of 845 days (IQR, 820-878 days) and with AI of 993 days (IQR, 968-1013 days; P < .001)
      • the recall rate decreased by 20.5% (3.09% before AI
      • 1875 of 60 751] vs 2.46% with AI
      • the cancer detection rate increased (0.70%
      • 423 of 60 751] vs 0.82%
      • the false-positive rate decreased (2.39%
      • 1452 of 60 751] vs 1.63%
      • the positive predictive value increased (22.6%
      • 423 of 1875] vs 33.6%
      • the rate of small cancers (≤1 cm) increased (36.6%
      • 127 of 347] vs 44.9%
      • the rate of node-negative cancers was unchanged (76.7%
      • 253 of 330] vs 77.8%
      • the rate of invasive cancers decreased (84.9%
      • 359 of 423] vs 79.6%
      • The reading workload was reduced by 33.5% (38 977 of 116 492 reads).
      • In total, 60 751 and 58 246 women were screened before and after AI system implementation
      • Lauritzen, A. D., Lillholm, M., Lynge, E., Nielsen, M., Karssemeijer, N., & Vejborg, I. (2024).
    2. Source 2:

      Experience with introduction of AI in Breast Cancer Screening in Capital Region of Denmark

      OrganizationCapital Mammography Screening Programme, conference slides hosted by Lægeforeningen, 2026By Ilse VejborgDocumentAccessed Nov 16, 202616 Nov 2026

      Supporting excerpts (45)
      • Uddannelseskonference for Yngre læger og Overlæger Middelfart 2026
      • Chief Physician and Head of Capital Mammography Screening Programme, Capital Region, Denmark
      • A collaboration between two Institutes at University of Copenhagen (Computerscience and Public Health), a professor and founder of the AI from Radboud University, NL and Capital Mammography Screening Programme
      • Results of Double blind readings by experienced full time breast radiologist of 114.421
      • Sampling period January 2014 - December 2015. 2 year follow up.
      • AI only (no radiologist readings) with a sensitivity matched to experienced breast radiologists
      • 100% work load reduction
      • Lower specificity than the radiologist (94.9% versus 98.1%)
      • Signifikant rise in FP: 276,5% rise - 5825 women compared to 2107
      • Transpara version 1.7.0 (We are now in Transpara version 2.1.0-B)
      • AI we have used is Transpara version 1.7.0 CE and FDA approved
      • Trained on > 1 mio. processed mammograms from different vendors in Europe and USA
      • Data from our regional screening programme was raw data ..and not included in the training
      • Procurement and implementation completed in a compressed process of 3 months in a strong collaboration between CIMT, Human Bytes / Transpara and clinical staff from the Breast Cancer Screening Program in RegionH
      • Main goal has been to reduce radiologist workload keeping quality indicators stable
      • 2 standardized views: CC + MLO
      • No clinical examination or UL
      • 6-10 minutes in the examination room at the screening clinics (radiographers)
      • <1-3 min. x 2/ exam centralized double blind readings (two radiologists)
      • Target group aged 50-69 år; 220.000 Q in RegionH
      • Mammograms analyzed by Transpara AI Local regional score Selection of highest regional score Stratification into risk categories on a scale from 1-100 Shown in PACS (in the end of the exam) 5 Screening Clinics in Capital Region, DK
      • Highest regional score decides the final risk score
      • AI has no previous exams to compare with- but the radiologists have them!
      • AI (first reader) + one breast radiologist (second reader) Consensus list in case of disagreement Allways a radiologist who decide!
      • Double blind readings as usual by two breast radiologists (with AI assistance) (no direct recall)
      • Danish National Mammography Screening program 2008-2020 National Performance Indicators (Danish Quality Database for Mammography Screening)
      • Even a small increase in recall rate decreases the benefit!
      • 1 diagnostic mammography (incl. clinical examination, Ul and evt. needle biopsy ) matches = 30-50 single readings
      • Women with a previous breast cancer diagnosis was highly prioritized over the normal screening population
      • distribution (4.6% /4.7%) of Q having history of BC operation before and after AI
      • Recall rate before increase of threshold: 2.72%
      • Recall rate after increase of threshold: 2.29%
      • In total with AI: 2.46%
      • Recall rate for low risk: 0.40%(14 cancers/ 53.438 us= detection rate 0,026%)
      • Recall rate for intermediate and high: 6.65%
      • Screening with AI as 1st reader (18th Nov. 2021- 31st December 2022) = 67.41% (53.438 / 79.270 screenings)
      • 14 cancers amongst 215 recalled women All cancers were new or lesions changed since last exam
      • With AI: 56,894 screenings from 18/11-2021 to 17/10-2022
      • Before AI: 60.751 screenings from 1/10-2020 to 17/11-2021
      • 7.Screening Round Before AI. (1st October 2020- 17th of November 2021; 63.682 q): 3.09%
      • 2.00 - 2.33 years 0.73% (0.63%, 0.84%) 1.03% (0.45%, 1.61%) 0.25 (ns)
      • 2.33 - 2.66 years 0.64% (0.53%, 0.75%) 0.96% (0.77%, 1.15%) 0.002 (**)
      • 2.66 - 3.00 years 0.66% (0.08%, 1.25%) 0.77% (0.68%, 0.87%) 0.74 (ns)
      • Early quality indicators show at least as good results as previously
      • Whats next? -Data on interval cancers
    3. Source 3:

      AI detects more breast cancers with fewer false positives

      IndependentRadiological Society of North America, Jun 4, 20244 Jun 2024Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (19)
      • Andreas D. Lauritzen, Ph.D., a post-doctoral student at the University of Copenhagen and researcher at Gentofte Hospital in Denmark.
      • Population-based screening with mammography reduces breast cancer mortality, but it places a substantial workload on radiologists who must read a large number of mammograms, the majority of which don't warrant a recall of the patient
      • The reading workload is further compounded when screening programs employ double reading to improve cancer detection and decrease false-positive recalls.
      • Mammograms deemed likely to be normal by AI were then read by one of 19 specialized full-time breast radiologists (called a single-read).
      • The commercially available AI system used for screening was trained by deep learning models to highlight and rate suspicious lesions and calcifications within mammograms.
      • All women who underwent mammographic screening were followed for at least 180 days.
      • In total, 60,751 women were screened without AI, and 58,246 women were screened with the AI system.
      • In the AI implementation group, 66.9% (38,977) of the screenings were single-read, and 33.1% (19,269) were double-read with AI assistance.
      • In the AI-screened group, the recall rate decreased by 20.5 percent, and the radiologists' reading workload was lowered by 33.4 percent,
      • The positive predictive value of AI screening was also greater than that of screening without AI (33.5% versus 22.5%).
      • All screening performance indicators improved except for the node-negative rate which showed no evidence of change,
      • Dr. Lauritzen said more research is needed to evaluate long-term outcomes and ensure overdiagnosis does not increase.
      • Radiologists typically have access to the women's previous screening mammograms, but the AI system does not,
      • That's something we'd like to work on in the future.
      • U.S. breast cancer screening protocols differ from protocols used in Denmark.
      • Images in a woman who had a Breast Imaging Reporting and Data System density of 2 and was 57 years old when she underwent screening with the artificial intelligence (AI) system.
      • The screening received a high AI examination score of 10 based on this lesion with a score of 89 out of 100.
      • Because of the high AI examination score, the screening was double read by two radiologists, who marked the same lesion (oval, A1) as the AI system, which led to recall.
      • Cropped US image shows a small (4 × 7 mm) invasive carcinoma (line) that was observed during the diagnostic workup.
    4. Source 4:

      AI Screening Assistance Could Safely Alleviate a Third of Radiologists Mammography Workload

      IndependentRadiological Society of North America, Oct 10, 202410 Oct 2024By Evonne AcevedoAccessed Nov 16, 202616 Nov 2026

      Supporting excerpts (20)
      • a commercially available AI system was implemented in November 2021 to automatically select screening mammograms for single or double readings based on the probability that breast cancer is present.
      • The AI system also aids radiologists by marking lesions in women at higher risk who are double-read.
      • from the Department of Computer Science at the University of Copenhagen, Denmark and Gentofte Hospital at the Capital Region of Denmark
      • AI is not taking over the radiologists' work
      • Rather, it assists and reallocates their time to more pressing tasks
      • Cases the AI selected for single reading encompassed about 70% of screenings
      • we observed that the cancer detection rate increased by 12 cancers per 10,000 screened women.
      • which could possibly indicate earlier detection.
      • Left mediolateral oblique full-field digital mammographic view in a 67-year-old woman
      • The screening received a high AI examination score of 10, based on this area with arterial calcifications being given a score of 85 out of 100 by the AI system.
      • Because of the high AI examination score, the screening was double read by two radiologists, who determined that the arterial calcifications (circle) did not yield suspicions for breast cancer. The woman was not recalled for diagnostic assessment.
      • While the double-reading approach to screening mammograms improves accuracy, it adds substantially to the ever-growing workload and staffing issues that plague the specialty, wrote Amie Y. Lee, MD, and Sarah M. Friedewald, MD, in an accompanying editorial.
      • Dr. Lee is an associate professor of radiology who oversees breast imaging informatics at the University of California, San Francisco, and Dr. Friedewald is associate professor and chief of breast imaging at Northwestern University's Feinberg School of Medicine in Chicago.
      • They recalled the landmark study in the American Journal of Roentgenology (2006) by Constance Lehman, MD, PhD, and colleagues that demonstrated no improvement in accuracy from computer-aided detection (CAD), despite decades in clinical use.
      • Although modern AI systems based on convolutional neural networks are superior to conventional CAD, repeating the same mistakes must be avoided and a dose of skepticism is warranted,
      • It provides additional evidence that AI can help decrease workload while simultaneously preserving, if not increasing, the interpretive performance of screening mammography.
      • The authors noted some of the study's limitations, which include the short follow-up period after screening (180 days) for biopsy and surgical outcomes. This minimum interval is too short to accurately assess false-negative findings, they asserted.
      • And while the cancer detection rate was higher with AI assistance, the proportion of ductal carcinoma in situ was greater
      • Thus, the higher rate of cancer detection with AI support may not necessarily translate to the desired goal of reducing interval cancers and improving patient outcomes,
      • Dr. Lauritzen and his team noted that results depend on the reading protocol, the radiologists and how the radiologists interact with the AI system.
    5. Source 5:

      An Artificial Intelligence-based Mammography Screening Protocol for Breast Cancer: Outcome and Radiologist Workload

      AcademicRadiological Society of North America, Jul 1, 20221 Jul 2022By Andreas D. Lauritzen, Alejandro Rodríguez-Ruiz, My Catarina von Euler-Chelpin, Elsebeth Lynge, Ilse Vejborg, Mads Nielsen, Nico Karssemeijer, and Martin LillholmAccessed Nov 16, 202616 Nov 2026

      Supporting excerpts (10)
      • This retrospective simulation study analyzed mammographic examination data consecutively collected from January 2014 to December 2015 in the Danish Capital Region breast cancer screening program.
      • All mammograms were scored from 0 to 10, representing the risk of malignancy, using an AI tool.
      • During simulation, normal mammograms (score < 5) would be excluded from radiologist reading and suspicious mammograms (score > recall threshold
      • would be recalled. Two radiologists read the remaining mammograms.
      • The RT was fitted using another independent cohort (same institution) by matching to the radiologist sensitivity.
      • The study sample comprised 114 421 screenings for breast cancer in 114 421 women
      • The AI-based screening sensitivity was 69.7%
      • was noninferior (P = .02) to the radiologist screening sensitivity of 70.8%
      • The AI-based screening specificity was 98.6%
      • The radiologist workload was reduced by 62.6% (71 585 of 114 421), and 25.1% (529 of 2107) of false-positive screenings were avoided.
    6. Source 6:

      The Lancet: AI-supported mammography screening results in fewer aggressive and advanced breast cancers, finds full results from first randomized controlled trial

      IndependentThe Lancet, Jan 29, 202629 Jan 2026Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (8)
      • despite European guidelines recommending two radiologists read mammograms
      • Double reading, where two radiologists read each mammogram, is standard practice in European screening programmes.
      • Lead author Dr Kristina Lång from Lund University, Sweden
      • over 100,000 women who were part of mammography screening at four sites in Sweden were randomly assigned
      • In the intervention arm, a specialist AI system analysed the mammograms and triaged low-risk cases to single reading and high-risk cases to double reading performed by radiologists.
      • The interim safety results of the MASAI trial, published in The Lancet Oncology in 2023
      • found a 44% reduction in screen-reading workload for radiologists.
      • a 12% reduction in interval cancer diagnosis for the AI arm
    7. Source 7:

      Aidoc expansion positions WellSpan as a leading AI-enabled health system

      OrganizationWellSpan Health, Dec 10, 202510 Dec 2025Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (3)
      • the leading health system serving central Pennsylvania and northern Maryland
      • Since first partnering in 2022, WellSpan has used Aidoc to enhance imaging triage and accelerate time-sensitive diagnoses.
      • In the past year alone, Aidoc analyzed more than 200,000 patient cases across WellSpan, flagging over 10,000 potentially critical findings, including pulmonary emboli, brain hemorrhages and vessel occlusions.
    8. Source 8:

      Active Reprioritization of the Reading Worklist Using Artificial Intelligence Has a Beneficial Effect on the Turnaround Time for Interpretation of Head CT with Intracranial Hemorrhage

      AcademicRadiology: Artificial Intelligence, Nov 18, 202018 Nov 2020Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (3)
      • University of Texas Southwestern Medical Center at Dallas
      • Active reprioritization of the worklist significantly reduced the wait time for examinations with artificial intelligence (AI)
      • 12.01 minutes per study during phase 3 vs 15.75 minutes per study during baseline
    9. Source 9:

      Real world multicenter analysis of stroke workflow with an AI care coordination platform (VALIDATE)

      AcademicFrontiers in Stroke, Jun 6, 20246 Jun 2024Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (2)
      • Acute stroke consultations seen by TeleSpecialists, LLC physicians at 166 facilities (17 states) utilizing Viz.ai software (AI) vs. no AI software (non-AI)
      • Arrival-to-NIR notification in the AI cohort was: (1) 39.5 min faster (44.13% reduction, p < 0.001) in the overall analysis
    10. Source 10:

      K241831: Transpara (2.1.0)

      Product documentationU.S. Food and Drug Administration, Nov 25, 202425 Nov 2024Accessed Nov 16, 202616 Nov 2026

      Supporting excerpts (5)
      • ScreenPoint Medical B.V.
      • Transpara software is intended for use as a concurrent reading aid for physicians interpreting screening full-field digital mammography exams and digital breast tomosynthesis exams
      • Output of the device includes locations of calcifications groups and soft-tissue regions, with scores indicating the likelihood that cancer is present, and an exam score indicating the likelihood that cancer is present in the exam.
      • Patient management decisions should not be made solely on the basis of analysis by Transpara.
      • Furthermore, temporal comparison has been included to allow a comparison of the current exam with prior exams.

    More in Production & Quality

    View all