Machine learning helps PG&E catch 17 potential ignitions
PG&E runs machine-learning models over smart meter and grid sensor data in a San Ramon monitoring center, so engineers can send crews to failing equipment before it sparks a wildfire or an outage.
Pacific Gas and Electric CompanyUnited States (Northern and Central California)Electric powerIn production since Jan 2024
- Scale
- Data from about 5.5 million SmartMeters and tens of thousands of grid sensors
- Scenario
- Grid condition monitoring for wildfire prevention
- Business function
- Energy and asset operations
- Kind of solution
- Predictive maintenance
- Who built it
- With Palantir and Texas A&M University
- Human oversight
- Assists people
- Organization
- Enterprise, part of PG&E Corporation
- AI types
- Machine learning
- People served
- more than 16 million people
- Sites
- 1295
tl;drPG&E's grid monitoring intercepted 17 potential ignitions in high fire-risk areas in 2025.See the results
Pacific Gas and Electric Company (PG&E) runs a Continuous Monitoring Center in San Ramon, California, where engineers use machine-learning models to watch its electric grid1. PG&E unveiled the center in May 20261.
The models scan data from tens of thousands of grid sensors and about 5.5 million SmartMeters for early signs of failing equipment1. The team then sends crews to fix the equipment before it turns into a wildfire or an outage1. One of the models, a transformer failure predictor called IONA, led to 282 field investigations in 2024 and 44 transformers replaced before they failed3.
The center brings together monitoring tools that PG&E built over several years. In 2025, those tools intercepted 17 potential ignitions in high fire-risk areas, avoided 12 million minutes of unplanned customer outages, and saved about $6 million in operating costs1, 4.
Before the deployment
PG&E serves more than 16 million people across 70,000 square miles of Northern and Central California1. When it filed for bankruptcy early in 2019, it cited potential liabilities of more than $30 billion stemming from wildfires5. Its defenses include undergrounding, covered power lines, vegetation management, cameras, weather stations, enhanced powerline safety settings, public safety power shutoffs, and monitoring technologies4.
Monitoring lagged behind the other defenses, because distribution equipment rarely fails in a way anyone can see. Before the center, the work had the following problems:
- Hidden deterioration: Clamps, switches, conductors, and connectors deteriorate over weeks or months. They change the current on a line only slightly before they fail, perhaps in a high wind5.
- Limited inspection: Deterioration is hard or impossible to see, so visual inspection and preventive maintenance help only marginally, as Texas A&M said in 20195.
- Reactive crews: Utilities had little choice but to wait and react to failures5. At PG&E, crews responded after something went wrong2.
- Early-stage monitoring: In its 2026-2028 wildfire mitigation plan, filed in its final revision in December 2025, PG&E said it was in the early stages of building real-time monitoring of its assets. It gave accelerating weather volatility as the reason3.
What was built
The center finds failing equipment in grid data, and engineers send crews to fix it before it causes harm1, 2. PG&E describes the change as moving from reacting to incidents to preventing them1. The work is divided as follows:
- Grid Data Analytics & Technology Platform: Pulls incoming sensor and outage data into one system1.
- Machine-learning models: Scan that data continuously for patterns that often show up before equipment fails, outages occur, or fires start2. SmartDetect finds anomalies in SmartMeter data, and IONA predicts which transformers will fail1, 3.
- Engineers: When something looks off, a trained team reviews it and decides whether to send a crew2. At PG&E’s Asset Health & Performance Center, engineers analyze the failure predictions that IONA generates. A reviewer confirms each voltage or load anomaly, assigns a likely root cause, and sends the case on for investigation3.
- Troubleshooters and crews: Go out when desktop analysis of a sensor alert calls for a field investigation, and confirm the condition on site1, 3.
- Maintenance programs: PG&E’s existing maintenance programs and funding fix the risks that IONA surfaces. IONA has no repair program of its own3.
PG&E set up the center to bring these capabilities into a single, integrated operation. The aim was faster analysis, stronger coordination, and more proactive risk detection1.
“When you listen to your assets, it’s like listening to a person. You can’t really understand somebody by just looking at them.”
Rollout
The parts arrived one at a time, and each tool produced alerts of its own. The transformer failure model started in a project called EPIC 3.20 and then moved into the IONA project3.
The plan adds line sensors at 240 more locations and DFA sensors at 15 more locations each year from 2026 to 2028, mostly in Tier 2 and Tier 3 high fire-threat districts3.
Technology and architecture
The following table lists the components of the solution.
| Layer | What they used | Role | Source |
|---|---|---|---|
| Anomaly detection model | SmartDetect | Finds patterns and anomalies in SmartMeter data that may indicate emerging risks | 1 |
| Predictive model | IONA | Predicts transformer failures from SmartMeter voltage and loading data, weather, transformer age and location | 3 |
| Operations console | Continuous Monitoring Center | Engineers review flagged anomalies and dispatch crews | 1, 2 |
| Sensors and telemetry | SmartMeter network | About 5.5 million meters scanning grid conditions | 1 |
| Sensors and telemetry | Line Sensors | Detect changes in current to locate issues across 19,000+ circuit miles | 1 |
| Sensors and telemetry | Distribution Fault Anticipation Sensors | Detect small disturbances across 8,900+ circuit miles | 1, 3 |
| Sensors and telemetry | Early Fault Detection Sensors | Radio-frequency monitoring for partial discharge and arcing across 900 circuit miles | 1 |
| Sensors and telemetry | GridScope Devices | Pole-mounted sensing of mechanical disturbances across 1,350+ circuit miles | 1, 3 |
| Sensors and telemetry | Downed Conductor Detection | Locates disturbances such as a fallen line | 1 |
| Data platform and storage | Grid Data Analytics & Technology Platform | Integrates sensor and outage data into one system | 1 |
| Data platform and storage | Palantir Foundry | Holds line sensor and DFA data and tracks alerts and field findings | 3 |
| Simulation or surrogate model | CYME power flow tool | Circuit model impedance for estimating fault location | 3 |
Data inputs
Each kind of sensing sees a different kind of trouble. The center reads the following data:
- SmartMeter readings: Voltage at the customer end of the line, which SmartDetect and IONA read1, 3. IONA gives each transformer a failure score, written “Pf” in the plan, that updates weekly3.
- Line sensor readings: Current, reported every 15 minutes or when fault current crosses a threshold. Crews use it to locate issues and find root causes1, 3.
- DFA waveforms: Current and voltage at 256 samples per cycle, to catch abnormal power flow events and small disturbances1, 3. Texas A&M, which developed DFA, describes it as software that interprets the variations in current that deteriorating equipment causes5.
- Early Fault Detection readings: Radio-frequency readings of partial discharge, an indicator of electrical degradation or arcing. The sensors can also pick up vegetation encroachment1, 3.
- GridScope readings: Mechanical disturbances on the pole, such as vibrations, acoustics, infrared light, and visible light. They pinpoint where an issue is and what it is1, 3.
- Downed conductor alerts: The location and cause of disturbances such as a fallen line1.
Integrations
The data meets in PG&E’s analytics platform. Since 2020, PG&E has been putting its most important asset and wildfire data into Palantir Foundry3. The analysis uses the following systems:
- Palantir Foundry: Draws on more than 50 separate source systems, line sensor and DFA data among them. Sensor alerts and the findings of the field investigations they trigger are tracked there3.
- CYME power flow tool: Supplies the circuit model impedance from which Foundry estimates the approximate area of a fault or disturbance. Repeated events accumulate, so the tool can use them to place anomalies more precisely3.
Because the plan places the sensor data and the alert tracking in Foundry, the Grid Data Analytics & Technology Platform in the release is most likely the same work under another name.
How one good catch flows through the system
PG&E calls a problem found and fixed before it causes harm a “good catch”. One came in 2025 on the Brunswick 1106 circuit in Nevada County1, 2:
- An engineer at the center flagged an anomaly that showed up as a small but unusual signal. The machine-learning model had identified a possible wiring issue1, 2.
- An electric troubleshooter went to the location. They found melted insulation at the transformer, where connections had degraded under severe weather-related stress1.
- Crews replaced the transformer and the equipment around it before an ignition could occur1.
The system caught a problem that the crew would never have known to look for2.
Had the transformer ignited, PG&E estimates, it could have led to a 17-acre wildfire, damaging two or three structures and causing up to $1.4 million in losses1.
Results
The 2025 figures cover the continuous monitoring capabilities that the center now runs, before it opened in May 20261. The following table lists the results.
| Metric | Before | After | Scope and timeframe | Reported by |
|---|---|---|---|---|
| Potential ignitions intercepted | Not disclosed | 17 potential ignitions | High fire-risk areas, 2025 | PG&E, measured1, 4 |
| Unplanned customer outage minutes avoided | Not disclosed | 12 million minutes | PG&E grid, 2025 | PG&E, estimated1, 4 |
| Transformers replaced before failure | Not disclosed | 44 transformers | 282 IONA investigations, 2024 | PG&E, measured3 |
| Operational costs saved | Not disclosed | about $6 million | PG&E grid, 2025 | PG&E, estimated1 |
| Emergency outage response time | Not disclosed | 2,620 hours less | PG&E grid, 2025 | PG&E, estimated1, 4 |
The metrics measure the following:
- Potential ignitions intercepted: Conditions in high fire-risk areas that crews found and fixed before they could start a fire1.
- Outage minutes, response hours, and cost savings: Counts of what PG&E judges it avoided. They’re estimates against an outcome that didn’t happen1, 4.
- Transformers replaced before failure: Nine of the 44 were in Tier 2 and 3 high fire-threat areas. Another 104 investigations turned up other risks that were repaired, such as loose or broken neutrals, broken jumpers, wiring issues, and failed fuses3.
- Good catches: PG&E has recorded 1,484 good catches across the grid since 20251.
- GridScope results: In its first rollout, GridScope found ten hazards on energized conductors before any outage. On June 27, 2024, its data cut the typical outage duration at one Placerville 2106 location by 70%, from 283 minutes to 88 minutes3. That duration, CAIDI, is the average time to restore a customer.
Lessons learned
The IONA results are the most useful figures, because PG&E’s plan sorts all 282 investigations by outcome. The categories are successful interventions, successful predictions, non-risk issues, and false positives3. IONA also led crews to broken neutrals, jumpers, and wiring problems, which PG&E counts as a benefit to its ignition risk reduction3.
Every alert passes two human checks before a repair. An engineer confirms each anomaly before anyone is dispatched, and a troubleshooter confirms it again on site3. The repair goes through the maintenance programs that the utility already runs, so the models add a way of finding risk without a second repair organization3. Because existing programs pay for those repairs, PG&E said IONA has no risk-spend efficiency figure of its own3.
More than a third of the IONA investigations in 2024 found nothing to fix. Of the 282 cases that the model shortlisted, 101 were non-actionable, such as circuit outages and SmartMeter data issues, and six were false positives3. PG&E plans to retrain IONA on the 2024 desktop reviews and field findings to improve its accuracy3. Texas A&M’s Russell and Benner, who developed DFA, have said that it will not detect all utility failures5.
The 2025 figures are PG&E’s own, from its press release, and Daily Energy Insider repeated three of them as what the company said1, 4. The release headline says the hub “Helped Prevent 17 Wildfires”, where its text speaks of potential ignitions intercepted1. IONA’s breakdown is public because the 2026-2028 plan had to provide all of its testing results, after PG&E had not committed to reporting them or IONA’s risk-spend efficiency3.
When the plan was filed, line sensor and DFA data were still being integrated into the analytics platform, and Early Fault Detection data was only planned for it3. GridScope covered about 3.5% of circuit miles in the high fire-threat and high fire-risk areas, and PG&E had no calculation yet of how much it reduces wildfire risk while testing went on3. The coverage in the May 2026 release shows that the sensor network has grown since1.
PG&E’s Currents feature says the center pulls data from more than 5.5 million sensors, while the release counts tens of thousands of sensors plus about 5.5 million meters1, 2. Daily Energy Insider places the center in PG&E’s dispute with the California Public Utilities Commission, which wants undergrounding in the right places at the right cost4. It notes that the more precisely risk can be measured, the stronger the case for deciding where expensive hardening belongs4.
Case study scorecard
- 17 potential ignitions Potential ignitions intercepted in high fire-risk areas1, 4
- 12 million minutes Unplanned customer outage minutes avoided1, 4
- 44 transformers Transformers replaced before failure after IONA investigations3
- about $6 million Operational costs saved1
Sources by publication date
- Organization 3
- Vendors and partners 1
- Press, academic, and regulators 2
Build this solution yourself
Analysis
What you need
To build this solution, you need the following in place:
- Meters that report voltage across the grid: PG&E’s network of about 5.5 million meters gave IONA and SmartDetect data to read across the whole grid1, 3.
- One analytics platform for asset, outage, and sensor data: Years of integration gave each alert a place to land and be tracked to a field outcome3.
- A loop back from the field: An engineer and a troubleshooter check each prediction, and the outcome is recorded as a fix, a non-issue, or a false positive. That record makes retraining possible3.
Reference architecture
Predictive maintenance
A predictive maintenance solution reads sensor data or fault codes from equipment in service and flags a unit that is drifting toward failure, so that the repair is planned before the breakdown. Readings go from the equipment to a data platform, where models score each unit and rules turn a score into an alert. Maintenance engineers or the equipment's owner act on each alert, and planners or a support team see the repair through.
- Sensors on the equipment (documented in this case study)
- Data link
- Monitoring platform
- Data platform (documented in this case study)
- Maintenance records
- Anomaly detection models (documented in this case study)
- Failure prediction models (documented in this case study)
- Alert thresholds and rules
- Alert review workbench
- Alert notifications
- Outcome record
A check mark shows a building block that this case study's sources document.
Open the reference architectureOthers who built it
In the library
- Predictive maintenance avoids 1,343 cancellations at easyJet easyJet
- How Nationwide uses Ting sensors to prevent electrical fires Nationwide
- Collins Aerospace's AI spots aircraft part wear early Collins Aerospace
- Stedin plans grid maintenance with machine learning Stedin
- Equinor's Omnia.Prevent watches over 700 rotating machines Equinor
- Bridgestone predicts car maintenance needs with My Speedy Bridgestone EMEA
Cite this case study
Enterprise AI Case Studies. "Machine learning helps PG&E catch 17 potential ignitions." Updated Nov 19, 2026. https://case-studies.ai/case-studies/operational-technology/OT-018-grid-fault-monitoring-wildfire-pge/
@misc{csai-ot-018,
author = {{Enterprise AI Case Studies}},
title = {{Machine learning helps PG&E catch 17 potential ignitions}},
year = {2026},
note = {Updated 2026-11-19},
url = {https://case-studies.ai/case-studies/operational-technology/OT-018-grid-fault-monitoring-wildfire-pge/}
}Sources
The following reporting, and every passage quoted from it, belongs to its publisher, not to this site. Sources and ownership
- Source 1:
Supporting excerpts (27)
today Pacific Gas and Electric Company (PG&E) unveils its new Continuous Monitoring Center (CMC), a first-of-its-kind centralized hub
The Continuous Monitoring Center in San Ramon brings together people, data and advanced machine learning from tens of thousands of sensors installed across PG&E's electric grid, combined with data from its smart meter network consisting of approximately 5.5 million meters that are scanning grid conditions.
By analyzing this data continuously, trained experts can identify emerging issues—often before customers are impacted—and dispatch crews to take action before those issues escalate into wildfires or outages.
Machine-learning models scan for patterns that indicate potential risks, allowing PG&E to move from reacting to incidents to preventing them altogether.
In 2025, the continuous monitoring capabilities delivered measurable results for customers and communities, including:
Intercepted 17 potential ignitions in high fire-risk areas
Avoided 12 million minutes of unplanned customer outages
Reduced emergency outage response time by 2,620 hours
Saved approximately $6 million in operational costs
Building on these early results, PG&E established the Continuous Monitoring Center to bring these capabilities into a single, integrated operation, allowing for faster analysis, stronger coordination and more proactive risk detection to further enhance safety and reliability.
The threat of wildfire requires more than incremental improvement, it demands a different kind of vigilance
With the Continuous Monitoring Center, we're adding another layer of protection, using predictive intelligence from millions of data points across our system, to spot problems forming before they become emergencies.
We are also actively sharing what we've learned with utilities and industry peers around the world.
said Mark Quinlan, PG&E's Senior Vice President of Wildfire, Emergency and Operations
the Continuous Monitoring Center team of engineers caught an issue, which they describe as a "good catch", on the Brunswick 1106 circuit in Nevada County.
The machine learning model identified a possible wiring issue and, after traveling to the location, an electric troubleshooter found melted insulation at the transformer caused by degraded connections because of severe weather-related stress.
Crews replaced the transformer and other associated equipment before an ignition could occur.
Had an ignition resulted, it could have led to a 17-acre wildfire, potentially damaging two or three structures and causing up to $1.4 million in losses.
Since 2025, PG&E has recorded 1,484 good catches.
Early Fault Detection Sensors – Radiofrequency (RF) monitoring that identifies partial discharge, arcing, and insulation breakdown, across 900 circuit miles in high fire-risk areas
GridScope Devices – Pinpoint the location and nature of issues across 1,350+ circuit miles in high fire-risk areas allowing for quick response and remediation.
Downed Conductor Detection – Enable fast identification of the location and cause of disturbances across 1,350+ circuit miles, supporting quicker response and targeted repairs.
SmartDetect – Uses SmartMeter™ data and machine learning to monitor grid performance, identify patterns and anomalies that may indicate emerging risks.
Distribution Fault Anticipation Sensors – Identify small system disturbances across 8,900+ circuit miles that enable proactive maintenance to prevent outages or risks before they occur.
Line Sensors – Detect changes in electric current patterns that help crews locate issues faster and determine root causes for more effective repairs across 19,000+ circuit miles.
Grid Data Analytics & Technology Platform – Integrates incoming sensor and outage data across PG&E's electric grid into a single system to help identify trends, prioritize preventative work and inform faster decision-making.
serving more than 16 million people across 70,000 square miles in Northern and Central California
- Source 2:
How PG&E Is Catching Wildfire Risks Before They Start
Supporting excerpts (12)
When an engineer at PG&E's newest facility flagged an anomaly on a circuit in Nevada County last year, it showed up as a small but unusual signal.
A field crew went out to investigate.
melted insulation on a transformer, its connections weakened by severe weather stress
The system has caught a problem the crew never would have known to look for.
The center pulls data from more than 5.5 million sensors across the grid.
Machine learning models scan that data continuously.
They look for patterns that often show up before equipment fails, outages occur or fires start.
When something looks off, a trained team reviews it and decides whether to send a crew.
In the past, crews responded after something went wrong.
A Grid Data Analytics Platform ties it all together.
When you listen to your assets, it's like listening to a person. You can't really understand somebody by just looking at them.
Craig Kurtz, PG&E's senior director of Continuous Monitoring
- Source 3:
PG&E Wildfire Mitigation Plan R3, 2026-2028, Volume 1 of 2
Supporting excerpts (53)
Docket Title: 2026 to 2028 Electrical Corporation Wildfire Mitigation Plans
We are in the early stages of building real-time monitoring to obtain more dynamic insight into the state of our electric assets in response to accelerating weather volatility.
Upon the completion of EPIC 3.20, the transformer failure prediction model transitioned to the IONA project.
IONA is a machine learning model that detects voltage anomalies using SmartMeter voltage and loading data along with weather data, transformer age, and geographical information to predict transformer failures.
The model assigns a Pf that updates weekly.
PG&E's Asset Health & Performance Center has been running the IONA model consistently since January 2024, conducting engineering analysis on failure predictions generated by the model.
Once the voltage/load anomalies are confirmed, a potential root cause is assigned by the reviewer and sent on for further investigation.
In 2024, 282 investigations were completed using the IONA model, which resulted in 44 transformers (9 in HFTD Tier 2 and 3 areas) being replaced prior to failure
There were 104 cases (23 in HFTD Tier 2 and 3 areas) where investigations revealed other system risks (e.g., loose/broken neutral, broken jumpers, wiring issues, circuit reactive component issues, failed fuses, energy theft) that were remediated.
101 of the cases shortlisted for investigation by the model were non-actionable—these included circuit outages, SmartMeter (non-billing) data issues etc.
False Positive Prediction 5 1 6 – False positive prediction by model
The IONA Program provides eyes on risk, then risk remediation is accomplished through existing maintenance programs and funding.
PG&E plans to re-train the IONA model based on results from desktop reviews and field investigation findings conducted in 2024 to improve model accuracy.
The IONA model has shown the capability to identify system risks over and above transformer issues, which is beneficial to PG&E ignition risk reduction efforts.
In its 2025 WMP Update, PG&E stated it will conduct tests to evaluate the accuracy of the IONA model and operationalize the model if it can achieve beneficial risk-spend efficiency.
PG&E does not commit to reporting on test results or calculated risk-spend efficiencies.
All testing results and documentation, reports, and/or whitepapers relevant to the IONA project.
15 minutes/triggered by fault magnitude threshold.
256 samples per cycle
In process of being integrated into analytics platform.
Plan to integrate into analytics platform.
PG&E has 1295 Line Sensor locations on 297 circuits and one DFA sensor each on 96 circuits as of end-of-year 2024.
PG&E plans to install Line Sensors on 240 additional locations each year and 15 DFA locations each year between 2026 and 2028.
These sensors will be predominantly located in Tier 2 and Tier 3 HFTD.
The data from these systems have been integrated into Foundry so that the data can be analyzed and approximate area of possible fault or disturbance calculated based on the circuit model impedance from the CYME power flow tool.
the tool can use the accumulated data to better determine anomaly locations.
Processes and procedures have been developed to track field investigations and resulting risk mitigation activities that are initiated based on line sensor/DFA-triggered alarms.
As of December 31, 2024, PG&E has deployed EFD sensors at 203 locations on eight circuits.
EFDs provide early detection of failing equipment and have the potential to detect vegetation encroachment.
PG&E has plans to integrate EFD data into the Foundry analytics platform.
EFD measurements are verified by monitoring the RF spectrum of the system for generated PD indications, which are an indicator of equipment electrical degradation or arcing.
The technology is installed directly onto distribution poles and detects mechanical disturbances (i.e., vibrations, acoustics, infrared light, and visible light).
Gridscope is not designed to operate as a distribution protection device the way a traditional circuit breaker, line recloser, or fuse would by detecting a fault and opening a circuit.
Gridscope began as a pilot of the EPSS Program in 2023, and we further expanded deployment of the devices in 2024.
To date, over 10,080 devices have been installed on 37 circuits in 95 circuit protection zones in the HFRA.
in our initial limited rollout of the technology we found ten instances where hazards were detected on energized conductors before any outage occurred.
instance on June 27, 2024, an outage on Placerville 2106, at a location that traditionally would generate an average CAIDI of 283 minutes, Gridscope data allowed troubleshooters to locate the specific fault location and reduce typical CAIDI by 70 percent to 88 minutes.
approximately 3.5 percent of the circuit miles in the HFTD and HFRA benefit from having Gridscope sensors on poles.
PG&E is currently undergoing testing to determine Gridscope effectiveness.
There is no calculation available for estimating the effectiveness for reducing wildfire risk at this time.
Next generation SmartMeter platforms combine edge computing, real-time analytics, and machine learning enabling distributed intelligence-based applications
develop a path to production if technology is found to be viable (SA-14).
4) Conduct pilots of selected technologies;
5) Evaluate the performance of different technologies against quantitative performance metrics; and
Sensor installation completions are tracked in the Enterprise Workflow management system (SAP).
verification of successful communication of sensors with their respective head-end systems
Installation documentation and sensor communication reports are audited by our Compliance and Operational Assurance (COA) Team.
PG&E's Asset Health and Performance Center reviews alerts from deployed sensors.
If desktop analysis indicates the need for further review, a field investigation is requested.
Any field findings and resulting remediations are tracked on the analytics platform Foundry enabling us to assess effectiveness of sensor technologies in reducing wildfire risk.
Since 2020, PG&E has been systematically integrating and providing access to its most critical electric asset and wildfire related data in our Enterprise analytics platform – Palantir Foundry
PG&E has integrated physical asset, operational, lifecycle, and environmental data from over 50 existing disparate, purpose-built data systems into Palantir Foundry.
Hence the IONA Program by itself does not have a Risk Spend Efficiency calculation.
- Source 4:
Utilities turn to AI as another line of defense against wildfires
Supporting excerpts (6)
in May unveiled a Continuous Monitoring Center in San Ramon that combines machine learning and data from the utility's monitoring systems.
The center intercepted 17 potential ignitions in high-fire-risk areas during 2025, while also avoiding 12 million minutes of unplanned customer outages and cutting emergency response time by 2,620 hours, said the company.
the systems are designed to identify electrical abnormalities, locate problems, and allow crews to target emerging equipment failures before they become fires or outages.
its mitigation portfolio includes undergrounding, covered power lines, vegetation management, cameras, weather stations, enhanced powerline safety settings, public safety power shutoffs, and monitoring technologies.
The CPUC, on the other hand, wants to ensure undergrounding occurs in the right places, at the right cost, and with adequate protections for ratepayers.
the more precisely risk can be measured, the stronger the case for deciding where expensive physical hardening makes sense.
- Source 5:
Texas A&M develops tool to predict power failures that lead to wildfires
Supporting excerpts (7)
It is a software that interprets variations in electrical currents on utility circuits caused by deteriorating conditions or equipment.
The devices often deteriorate over weeks or months, impacting electrical currents in small ways before an actual failure — perhaps triggered by high winds.
Until now, utility companies have had little choice but to wait and react to failures.
Electrical equipment is extremely durable and deterioration of devices is difficult or impossible to see. That makes visual inspection and preventive maintenance only marginally helpful.
While Russell and Benner emphasize that DFA will not detect all utility failures
Pacific Gas & Electric is now testing six DFA circuit monitoring devices; Southern California Edison is testing 60 DFA monitors. Both utilities are conducting the tests under two-year research contracts with Texas A&M.
PG&E filed for bankruptcy this past January, citing potential liabilities of more than $30 billion stemming from wildfires.
- Source 6:
Predicting Distribution Transformer Failures
Supporting excerpts (1)
ComEd uses machine learning on AMI data to monitor and track distribution system transformer health.
Comments
Start the conversation.
Invited members of the library comment here. Sign in to join the conversation.